Web orders only - FREE shipping via UPS Ground (continental US only, motor freight excluded)
 
 
 
 
 
  BRAKE PRODUCTS
78,347 part numbers: Brake Wheels & Discontinued Brake Parts
  GEMCO
14,221 part numbers: Motion Control Products
 
  GLEASON
23,582 part numbers: Cable & Hose Management Systems
  AERO-MOTIVE
3,746 part numbers: Cable & Hose Management Systems
  CUTLER-HAMMER
6,312 part numbers: Electrical Control Products
 
 
 
 
 
  STEARNS
6,604 part numbers: Motor Mounted Brakes
  HUBBELL
16,262 part numbers: Electrical Control Products
  SUPERBOLT
110 part numbers: Fastening Solutions
  TELEMOTIVE
2,458 part numbers: Radio Remote Control
  RENOLD
399 part numbers: Mechanical Power Transmission Products
 
 

Aero-Motive Direct
Amazon Store

 
73 part numbers
 

Brake Products
Amazon Store

 
471 part numbers
 
 
Brake Products is now an authorized distributor of

 
 
Web: www.stearns-direct.com Email: sales@stearns-direct.com Phone: (888) 861-8777
 
Brakes and Replacement Parts: P/N 8-078-913-09
Parts List for 65,300-07 and 65,300-09 Series Brakes [P/N 8-078-913-09]

No Qty
Req'd
Item Part
Number
Description Picture Stock
Qty
Price
Each
Qty
Ord'd
Update
Cart
1 1 2 STE-5-50-5205-00 Call - 0 Call Call Call
2 1 16 STE-5-16-5015-00 Call - 0 Call Call Call
3 1 16A STE-9-17-1010-00 Call - 0 Call Call Call
4 1 16B STE-8-103-504-00 Call - 0 Call Call Call
5 1 16H STE-9-45-1330-00 Stearns Lock Washer Part 9-45-1330-00 Dated 1/17 - 0 $2.20
6 1 16D STE-9-01-6506-00 Stearns Ball bearing (hub) - 0 $139.49
7 1 16E STE-8-103-503-00 Call - 0 Call Call Call
8 1 16G STE-8-141-506-00 Call - 0 Call Call Call
9 1 3 STE-5-66-8354-00 Stearns Disc kit Part 5-66-8354-00 Stationary Disc Kit Dated 1/18 - 0 $51.48
10 1 3A STE-5-66-8355-00 Stearns Disc. Stationary Disc Kit, 2 Discs 1/15 - 0 $93.55
11 1 4 STE-5-66-8458-00 Stearns Friction Disc Part 5-66-8458-00 Spline Friction Disc Kit 50 Original Dated 1/18 - 2 $124.74
12 1 7 STE-5-07-5015-00 Call - 0 Call Call Call
13 1 148 STE-8-148-504-04 Call - 0 Call Call Call
14 1 148G STE-8-073-002-12 Call - 0 Call Call Call
15 1 15S STE-9-17-3220-00 Stearns Cap screw - 0 $5.54
16 1 156 STE-9-45-1332-00 Stearns Lock washer - 0 $1.85
17 1 20A STE-8-003-504-01 Stearns 65,300 insulator disc steel stamp-zinc phosphate - 0 $74.83
18 1 20P STE-9-32-2003-00 Stearns Pin Part 9-32-2003-00 Dated 1/17 (1LB) H 4" L 5" W 4" Box - 0 $1.93
19 1 21A STE-5-57-5001-00 Stearns 65,300 Thermo Switch-Closed Part 5-57-5001-00 Dated 1/18 - 2 $205.93
20 1 21B STE-5-57-5002-00 Stearns 65,300 Thermo Switch-Open Part 5-57-5002-00 Dated 1/18 - 0 $205.93
21 1 21S STE-9-13-3083-00 Call - 0 Call Call Call
22 1 21W STE-9-45-0325-00 Stearns Lock Washer Part 9-45-0325-00 Dated 1/17 - 0 $2.20
23 1 25 STE-9-23-0023-00 Call - 0 Call Call Call
24 1 70 STE-9-33-3004-00 Stearns Elbow - 0 $49.89
25 1 142 STE-5-42-5632-00-14 Stearns Support Plate Assembly Does not include the Coil - 0 $221.70
26 1   STE-5-42-5633-00-14 Stearns Support plate assembly (less coil) - 0 $207.85
27 1   STE-5-42-5634-00-14 Stearns Support plate assembly (less coil) - 0 $221.70
28 1   STE-5-42-5635-00-14 Stearns Support plate assembly (less coil) - 0 $221.70
29 1 142S STE-9-25-9013-00 Stearns Mounting screws - 0 $0.93
30 1 59 STE-9-71-0005-00 Stearns Release spring, Use 5-66-8755-00 - 0 $3.70
31 1 156 STE-8-156-510-00 Stearns Release arm - 0 $5.36
32 1 148 STE-8-148-504-04 Call - 0 Call Call Call
33 1 148R STE-9-03-0001-00 Stearns Retaining ring - 0 $1.85
34 1 148S STE-9-10-2706-00 Stearns Screw - 0 $1.85
35 1 Not shown STE-5-63-0539-00 Stearns Vertical Spring Kit (2 disc) - 0 $27.71
36 1 2G STE-5-63-0540-00 Call - 0 Call Call Call
37 1   STE-5-63-0541-00 Call - 0 Call Call Call
38 1 6 STE-8-006-501-00 Stearns Bearing Part 8-006-501-00 Sleeve Bearing Oilite 0.31 Inch Diameter 0.59 Inch Long Dated 1/17 - 0 $3.85
39 1 8 STE-8-008-504-01 Stearns Lever Part 8-008-504-01 56 Solenoid Lever Aluminum W/Fin Dated 1/17 (1LB) H 4" L 5" W 4" Box - 0 $43.55
40 1 8R STE-9-03-0057-00 Stearns Retaining Ring 11/16 - 0 $3.26
41 1 8W STE-9-45-0168-00 Stearns Lock Washer Part 9-45-0168-00 Dated 1/17 - 0 $2.20
42 1 11N STE-9-40-3928-00 Stearns Nut - 0 $3.70
43 1 10 STE-9-17-8420-00 Stearns Cap screw - 0 $11.09
44 1 11 STE-9-70-1215-00 Stearns Pressure Spring Part 9-70-1215-00 Ships in Dated 10/18 - 0 $3.96
45 1   STE-9-70-1523-00 Stearns Pressure spring - 0 $3.70
46 1   STE-9-70-1524-00 Stearns Pressure spring - 0 $3.70
47 1 11W STE-9-46-0010-00 Stearns Spring washer - 0 $1.85
48 1 17 STE-5-17-5011-00 Stearns 56,0,5&700 lever arm assembly - 0 $16.63
49 1 26 STE-9-29-4826-00 Stearns Pin - 0 $3.70
50 1 29A STE-8-094-503-00 Stearns Plunger Stop - 0 $3.78
51 1 126 STE-5-26-5021-00 Stearns Support Plate Part 5-26-5021-00 Support Plate & Spring Stud Assembly - 0 $33.25
52 1 131 STE-9-29-4836-00 Stearns Pin 1/17 - 0 $3.85
53 1 142S STE-9-25-9013-00 Stearns Mounting screws - 0 $0.93 Line #29 -
54 1 Z STE-5-66-5042-00 Stearns Solenoid Kit # 4 Solenoid Kit 5/17 - 0 $154.00
55 1 12 STE-5-96-6407-05 Stearns Coil Kit Part 5-96-6407-05 #4 Coil Kit 115 / 230 Volt AC 60 Hz Class "H" Insulation Dated 1/17 (2LBS) H 4" L 5" W 4 Box - 0 $492.80
56 1   STE-5-96-6409-05 Stearns Coil Kit Part 5-96-6409-05 #4 Coil Kit 230 / 460 Volt AC, 60 Hz Class "H" Insulation Dated 1/18 (2LBS) H 4" L 5" W 4 Box - 0 $506.88
57 1   STE-5-96-6401-05 Stearns Coil Kit Part 5-96-6401-05 #4 Coil Kit 115 Volt AC 60 Hz Class "H" Insulation Dated 1/17 (2LBS) H 4" L 5" W 4 Box - 0 $352.28
58 1   STE-5-96-6402-05 Stearns Coil Kit Part 5-96-6402-05 #4 Coil Kit 230 Volt AC 60 Hz Class "H" Insulation Dated 1/17 (2LBS) H 4" L 5" W 4 Box - 0 $352.28
59 1   STE-5-96-6404-05 Stearns Coil Kit Part 5-96-6404-05 #4 Coil Kit 460 Volt AC 60 Hz Class "H" Insulation Ships in 7 to 10 days, WI Dated 1/18 (2LBS) H 4" L 5" W 4 Box - 0 $362.34
60 1   STE-5-96-6405-05 Stearns Coil Kit Part 5-96-6405-05 #4 Coil Kit 575 Volt AC 60 Hz Class "H" Insulation Dated 1/17 (2LBS) H 4" L 5" W 4 Box - 0 $352.28
61 1   STE-5-96-6457-05 Stearns Coil kit Part 5-96-6457-05 #K4 Coil Kit 115 / 230 Volt AC 60 Hz Class "H" Insulation Dated 7/17 - 0 $466.81
62 1   STE-5-96-6459-05 Stearns Coil Kit Part 5-96-6459-05 230 / 460 Volt K-4 Coil Kit Class "H" Insulation / High Heat Ships in 10 days Dated 1/18 - 0 $480.15
63 1   STE-5-96-6451-05 Stearns Coil #K4 Coil Kit 115 Volt AC, 60 Hz Class "H" Insulation 4/17 - 0 $361.90
64 1   STE-5-96-6452-05 Stearns Coil Kit Part 5-96-6452-05 K4 Coil Kit 230 Volt AC 60 Hz Class "H" Insulation Ships in 10 days Dated 1/18 - 0 $372.24
65 1   STE-5-96-6454-05 Stearns Coil #K4 Coil Kit 460 Volt AC, 60 Hz Class "H" Insulation 8/16 - 0 $355.33
66 1   STE-5-96-6455-05 Stearns #K4 coil kit-575 Vac, 60 Hz, Cl. H - 0 $347.32
67 1   STE-5-96-6407-25 Stearns Coil Kit Part 5-96-6407-25 #K4+ Coil Kit 115 / 230 Volt AC 60 Hz Class "H" Insulation Dated 1/17 (2LBS) H 4" L 5" W 4 Box - 0 $466.81
68 1   STE-5-96-6409-25 Stearns Coil Kit Part 5-96-6409-25 #K4+ Coil Kit 230 / 460 Volt AC 60 Hz Class "H" Insulation Dated 1/18 (2LBS) H 4" L 5" W 4 Box - 0 $480.90
69 1   STE-5-96-6401-25 Stearns Coil Kit Part 5-96-6401-25 K4+ Coil Kit 115 Volt AC 60 Hz Class "H" Insulation Dated 1/17 (2LBS) H 4" L 5" W 4 Box - 0 $352.28
70 1   STE-5-96-6402-25 Stearns Coil Kit Part 5-96-6402-25 K4+ Coil Kit 230 Volt AC 60 Hz Class "H" Insulation Dated 1/1 (2LBS) H 4" L 5" W 4 Box - 0 $352.28
71 1   STE-5-96-6404-25 Stearns Coil Kit Part 5-96-6404-25 K4+ Coil Kit 460 Volt AC 60 Hz Class "H" Insulation Dated 1/1 (2LBS) H 4" L 5" W 4 Box - 0 $352.28
72 1   STE-5-96-6405-25 Stearns Coil Kit Part 5-96-6405-25 K4+ Coil Kit 575 Volt AC 60 Hz Class "H" Insulation Dated 1/17 (2LBS) H 4" L 5" W 4 Box - 0 $466.81
73 1 3 STE-5-66-8354-00 Stearns Disc kit Part 5-66-8354-00 Stationary Disc Kit Dated 1/18 - 0 $51.48 Line #9 -
74 1 3A STE-5-66-8355-00 Stearns Disc. Stationary Disc Kit, 2 Discs 1/15 - 0 $93.55 Line #10 -
75 1 4 STE-5-66-8458-00 Stearns Friction Disc Part 5-66-8458-00 Spline Friction Disc Kit 50 Original Dated 1/18 - 2 $124.74 Line #11 -
76 1 Z STE-5-66-5042-00 Stearns Solenoid Kit # 4 Solenoid Kit 5/17 - 0 $154.00 Line #54 -
77 1 Not shown STE-5-64-5039-00 Call - 0 Call Call Call
78 1 2G STE-5-63-0540-00 Call - 0 Call Call Call
79 1   STE-5-63-0541-00 Call - 0 Call Call Call
Easy Order Shortcuts
No Part
Number
Description Image Stock
Qty
Price
Each
Qty
Ord'd
Update
Cart
1 STE-1-065-311-09-BEC Stearns Series 65,300 (1-065-3XX-09) Brake, Fan-Guard Mount IP 23, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3X1-09 Series Hazardous Location Motor Mounted Brake is recommended for mounting to a motor fan guard or for use with a motor frame adapter Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [1] = 1.5 Enclosure [1] = IP 23 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [E] = Voltage: 200; 60 Hz Lead Wire Position [C] = Form 3 - 0 $2,302.91
2 STE-1-065-311-09-BQB Stearns Series 65,300 (1-065-3XX-09) Brake, Fan-Guard Mount IP 23, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3X1-09 Series Hazardous Location Motor Mounted Brake is recommended for mounting to a motor fan guard or for use with a motor frame adapter Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [1] = 1.5 Enclosure [1] = IP 23 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) Lead Wire Position [B] = Form 2 - 0 $2,302.91
3 STE-1-065-312-07-BLB Stearns Series 65,300 (1-065-3XX-07) Brake, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3XX-07 Series Hazardous Location Motor Mounted Brake is used for mounting close coupled (directly) to the motor end bell Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 56, and Hazardous Location NEMA 7, 9, UL Type 4 Certified: USL/CNL Listed, File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Note: 65,300 Series Close-Coupled Brakes (-07) must be mounted directly to motor endbell Nominal Static Torque (lb-ft) [1] = 1.5 Enclosure [2] = IP 56 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz) Lead Wire Position [B] = Form 2 - 0 $2,372.09
4 STE-1-065-312-07-BLC Stearns Series 65,300 (1-065-3XX-07) Brake, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3XX-07 Series Hazardous Location Motor Mounted Brake is used for mounting close coupled (directly) to the motor end bell Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 56, and Hazardous Location NEMA 7, 9, UL Type 4 Certified: USL/CNL Listed, File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Note: 65,300 Series Close-Coupled Brakes (-07) must be mounted directly to motor endbell Nominal Static Torque (lb-ft) [1] = 1.5 Enclosure [2] = IP 56 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz) Lead Wire Position [C] = Form 3 - 0 $2,372.09
5 STE-1-065-312-07-BQB Stearns Series 65,300 (1-065-3XX-07) Brake, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3XX-07 Series Hazardous Location Motor Mounted Brake is used for mounting close coupled (directly) to the motor end bell Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 56, and Hazardous Location NEMA 7, 9, UL Type 4 Certified: USL/CNL Listed, File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Note: 65,300 Series Close-Coupled Brakes (-07) must be mounted directly to motor endbell Nominal Static Torque (lb-ft) [1] = 1.5 Enclosure [2] = IP 56 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) Lead Wire Position [B] = Form 2 - 0 $2,372.09
6 STE-1-065-312-07-BQC Stearns Series 65,300 (1-065-3XX-07) Brake, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3XX-07 Series Hazardous Location Motor Mounted Brake is used for mounting close coupled (directly) to the motor end bell Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 56, and Hazardous Location NEMA 7, 9, UL Type 4 Certified: USL/CNL Listed, File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Note: 65,300 Series Close-Coupled Brakes (-07) must be mounted directly to motor endbell Nominal Static Torque (lb-ft) [1] = 1.5 Enclosure [2] = IP 56 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) Lead Wire Position [C] = Form 3 - 0 $2,372.09
7 STE-1-065-321-09-BBB Stearns Series 65,300 (1-065-3XX-09) Brake, Fan-Guard Mount IP 23, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3X1-09 Series Hazardous Location Motor Mounted Brake is recommended for mounting to a motor fan guard or for use with a motor frame adapter Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [2] = 3 Enclosure [1] = IP 23 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz Lead Wire Position [B] = Form 2 - 0 $2,400.56
8 STE-1-065-321-09-BLB Stearns Series 65,300 (1-065-3XX-09) Brake, Fan-Guard Mount IP 23, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3X1-09 Series Hazardous Location Motor Mounted Brake is recommended for mounting to a motor fan guard or for use with a motor frame adapter Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [2] = 3 Enclosure [1] = IP 23 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz) Lead Wire Position [B] = Form 2 - 0 $2,400.56
9 STE-1-065-321-09-BMB Stearns Series 65,300 (1-065-3XX-09) Brake, Fan-Guard Mount IP 23, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3X1-09 Series Hazardous Location Motor Mounted Brake is recommended for mounting to a motor fan guard or for use with a motor frame adapter Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [2] = 3 Enclosure [1] = IP 23 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz Lead Wire Position [B] = Form 2 - 0 $2,400.56
10 STE-1-065-321-09-BNC Stearns Series 65,300 (1-065-3XX-09) Brake, Fan-Guard Mount IP 23, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3X1-09 Series Hazardous Location Motor Mounted Brake is recommended for mounting to a motor fan guard or for use with a motor frame adapter Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [2] = 3 Enclosure [1] = IP 23 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz Lead Wire Position [C] = Form 3 - 0 $2,400.56
11 STE-1-065-321-09-BPB Stearns Series 65,300 (1-065-3XX-09) Brake, Fan-Guard Mount IP 23, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3X1-09 Series Hazardous Location Motor Mounted Brake is recommended for mounting to a motor fan guard or for use with a motor frame adapter Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [2] = 3 Enclosure [1] = IP 23 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz Lead Wire Position [B] = Form 2 - 0 $2,400.56
12 STE-1-065-321-09-BQB Stearns Series 65,300 (1-065-3XX-09) Brake, Fan-Guard Mount IP 23, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3X1-09 Series Hazardous Location Motor Mounted Brake is recommended for mounting to a motor fan guard or for use with a motor frame adapter Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [2] = 3 Enclosure [1] = IP 23 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) Lead Wire Position [B] = Form 2 - 0 $2,400.56
13 STE-1-065-322-07-BBB Stearns Series 65,300 (1-065-3XX-07) Brake, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3XX-07 Series Hazardous Location Motor Mounted Brake is used for mounting close coupled (directly) to the motor end bell Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 56, and Hazardous Location NEMA 7, 9, UL Type 4 Certified: USL/CNL Listed, File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Note: 65,300 Series Close-Coupled Brakes (-07) must be mounted directly to motor endbell Nominal Static Torque (lb-ft) [2] = 3 Enclosure [2] = IP 56 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz Lead Wire Position [B] = Form 2 - 0 $2,494.15
14 STE-1-065-322-07-BMB Stearns Series 65,300 (1-065-3XX-07) Brake, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3XX-07 Series Hazardous Location Motor Mounted Brake is used for mounting close coupled (directly) to the motor end bell Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 56, and Hazardous Location NEMA 7, 9, UL Type 4 Certified: USL/CNL Listed, File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Note: 65,300 Series Close-Coupled Brakes (-07) must be mounted directly to motor endbell Nominal Static Torque (lb-ft) [2] = 3 Enclosure [2] = IP 56 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz Lead Wire Position [B] = Form 2 - 0 $2,494.15
15 STE-1-065-322-07-BQB Stearns Series 65,300 (1-065-3XX-07) Brake, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3XX-07 Series Hazardous Location Motor Mounted Brake is used for mounting close coupled (directly) to the motor end bell Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 56, and Hazardous Location NEMA 7, 9, UL Type 4 Certified: USL/CNL Listed, File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Note: 65,300 Series Close-Coupled Brakes (-07) must be mounted directly to motor endbell Nominal Static Torque (lb-ft) [2] = 3 Enclosure [2] = IP 56 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) Lead Wire Position [B] = Form 2 - 0 $2,494.15
16 STE-1-065-331-09-BNB Stearns Series 65,300 (1-065-3XX-09) Brake, Fan-Guard Mount IP 23, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3X1-09 Series Hazardous Location Motor Mounted Brake is recommended for mounting to a motor fan guard or for use with a motor frame adapter Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [3] = 6 Enclosure [1] = IP 23 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz Lead Wire Position [B] = Form 2 - 0 $2,514.49
17 STE-1-065-331-09-BPB Stearns Series 65,300 (1-065-3XX-09) Brake, Fan-Guard Mount IP 23, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3X1-09 Series Hazardous Location Motor Mounted Brake is recommended for mounting to a motor fan guard or for use with a motor frame adapter Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [3] = 6 Enclosure [1] = IP 23 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz Lead Wire Position [B] = Form 2 - 0 $2,514.49
18 STE-1-065-331-09-BQB Stearns Series 65,300 (1-065-3XX-09) Brake, Fan-Guard Mount IP 23, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3X1-09 Series Hazardous Location Motor Mounted Brake is recommended for mounting to a motor fan guard or for use with a motor frame adapter Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [3] = 6 Enclosure [1] = IP 23 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) Lead Wire Position [B] = Form 2 - 0 $2,514.49
19 STE-1-065-332-07-BPB Stearns Series 65,300 (1-065-3XX-07) Brake, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3XX-07 Series Hazardous Location Motor Mounted Brake is used for mounting close coupled (directly) to the motor end bell Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 56, and Hazardous Location NEMA 7, 9, UL Type 4 Certified: USL/CNL Listed, File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Note: 65,300 Series Close-Coupled Brakes (-07) must be mounted directly to motor endbell Nominal Static Torque (lb-ft) [3] = 6 Enclosure [2] = IP 56 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz Lead Wire Position [B] = Form 2 - 0 $1,682.02
20 STE-1-065-332-07-CQB Stearns Series 65,300 (1-065-3XX-07) Brake, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3XX-07 Series Hazardous Location Motor Mounted Brake is used for mounting close coupled (directly) to the motor end bell Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 56, and Hazardous Location NEMA 7, 9, UL Type 4 Certified: USL/CNL Listed, File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Note: 65,300 Series Close-Coupled Brakes (-07) must be mounted directly to motor endbell Nominal Static Torque (lb-ft) [3] = 6 Enclosure [2] = IP 56 Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) Lead Wire Position [B] = Form 2 - 0 $2,636.55
21 STE-1-065-351-09-BFB Stearns Series 65,300 (1-065-3XX-09) Brake, Fan-Guard Mount IP 23, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3X1-09 Series Hazardous Location Motor Mounted Brake is recommended for mounting to a motor fan guard or for use with a motor frame adapter Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [5] = 10 Enclosure [1] = IP 23 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz) Lead Wire Position [B] = Form 2 - 0 $2,681.31
22 STE-1-065-351-09-BLB Stearns Series 65,300 (1-065-3XX-09) Brake, Fan-Guard Mount IP 23, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3X1-09 Series Hazardous Location Motor Mounted Brake is recommended for mounting to a motor fan guard or for use with a motor frame adapter Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [5] = 10 Enclosure [1] = IP 23 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz) Lead Wire Position [B] = Form 2 - 0 $2,681.31
23 STE-1-065-351-09-BNB Stearns Series 65,300 (1-065-3XX-09) Brake, Fan-Guard Mount IP 23, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3X1-09 Series Hazardous Location Motor Mounted Brake is recommended for mounting to a motor fan guard or for use with a motor frame adapter Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [5] = 10 Enclosure [1] = IP 23 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz Lead Wire Position [B] = Form 2 - 0 $2,681.31
24 STE-1-065-351-09-BQB Stearns Series 65,300 (1-065-3XX-09) Brake, Fan-Guard Mount IP 23, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3X1-09 Series Hazardous Location Motor Mounted Brake is recommended for mounting to a motor fan guard or for use with a motor frame adapter Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [5] = 10 Enclosure [1] = IP 23 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) Lead Wire Position [B] = Form 2 - 0 $2,681.31
25 STE-1-065-351-09-BQC Stearns Series 65,300 (1-065-3XX-09) Brake, Fan-Guard Mount IP 23, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3X1-09 Series Hazardous Location Motor Mounted Brake is recommended for mounting to a motor fan guard or for use with a motor frame adapter Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [5] = 10 Enclosure [1] = IP 23 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) Lead Wire Position [C] = Form 3 - 0 $2,681.31
26 STE-1-065-351-09-DBB Stearns Series 65,300 (1-065-3XX-09) Brake, Fan-Guard Mount IP 23, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3X1-09 Series Hazardous Location Motor Mounted Brake is recommended for mounting to a motor fan guard or for use with a motor frame adapter Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [5] = 10 Enclosure [1] = IP 23 Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz Lead Wire Position [B] = Form 2 - 0 $2,681.31
27 STE-1-065-352-07-BQB Stearns Series 65,300 (1-065-3XX-07) Brake, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3XX-07 Series Hazardous Location Motor Mounted Brake is used for mounting close coupled (directly) to the motor end bell Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 56, and Hazardous Location NEMA 7, 9, UL Type 4 Certified: USL/CNL Listed, File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Note: 65,300 Series Close-Coupled Brakes (-07) must be mounted directly to motor endbell Nominal Static Torque (lb-ft) [5] = 10 Enclosure [2] = IP 56 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) Lead Wire Position [B] = Form 2 - 0 $2,844.06
28 STE-1-065-352-07-BQC Stearns Series 65,300 (1-065-3XX-07) Brake, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3XX-07 Series Hazardous Location Motor Mounted Brake is used for mounting close coupled (directly) to the motor end bell Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 56, and Hazardous Location NEMA 7, 9, UL Type 4 Certified: USL/CNL Listed, File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Note: 65,300 Series Close-Coupled Brakes (-07) must be mounted directly to motor endbell Nominal Static Torque (lb-ft) [5] = 10 Enclosure [2] = IP 56 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) Lead Wire Position [C] = Form 3 - 0 $2,844.06
29 STE-1-065-361-09-BQB Stearns Series 65,300 (1-065-3XX-09) Brake, Fan-Guard Mount IP 23, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3X1-09 Series Hazardous Location Motor Mounted Brake is recommended for mounting to a motor fan guard or for use with a motor frame adapter Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 23 and Hazardous Location NEMA 7, 9 Certified: USL/CNL File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Nominal Static Torque (lb-ft) [6] = 15 Enclosure [1] = IP 23 Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) Lead Wire Position [B] = Form 2 - 0 $2,778.96
30 STE-1-065-362-07-DLC Stearns Series 65,300 (1-065-3XX-07) Brake, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3XX-07 Series Hazardous Location Motor Mounted Brake is used for mounting close coupled (directly) to the motor end bell Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 56, and Hazardous Location NEMA 7, 9, UL Type 4 Certified: USL/CNL Listed, File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Note: 65,300 Series Close-Coupled Brakes (-07) must be mounted directly to motor endbell Nominal Static Torque (lb-ft) [6] = 15 Enclosure [2] = IP 56 Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz) Lead Wire Position [C] = Form 3 - 0 $2,966.12
31 STE-1-065-362-07-DQB Stearns Series 65,300 (1-065-3XX-07) Brake, Division I Hazardous Location NEMA 7, 9: Enclosure Material: Cast Iron Mounting Requirements: 1-065-3XX-07 Series Hazardous Location Motor Mounted Brake is used for mounting close coupled (directly) to the motor end bell Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ Enclosure Protection: IP 56, and Hazardous Location NEMA 7, 9, UL Type 4 Certified: USL/CNL Listed, File E-14893, for Class I, Group C and D and Class II, Group F and G Class I, Zone 1, Group IIA and IIB Epoxy Encapsulated Coil Construction, with Class H Insulation Release Type: Knob, maintained with automatic reset Adjustable Torque Visual Wear Indicator Manual Wear Adjustment NC Thermostat Note: 65,300 Series Close-Coupled Brakes (-07) must be mounted directly to motor endbell Nominal Static Torque (lb-ft) [6] = 15 Enclosure [2] = IP 56 Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32 Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz) Lead Wire Position [B] = Form 2 - 0 $2,966.12
Secure Online Order
 

 
Secure Online Order
 
6,604 part numbers available for
online order
 
Shopping Cart
Empty
Checkout is secure
 
All products are covered by a $1,000,000 liability insurance:
Click to view the Certificate
 

Products Available From Stock
Free shipping via UPS Ground (continental US only, motor freight excluded)
 
Web Site Features
 
Part Number Lookup
 
Enter at least three characters of a Stearns part number to retrive the list of all documents (such as specifications, manuals, guides, drawings, etc.) from our web site, referencing this part number:
 
Part Number:

 
Search scope:
This web site only
All BPI web sites
 
Formal PDF Quotation
 
To obtain an instant formal printable PDF quotation use shopping cart and select "View PDF Quote", instead of checking out. Click here for instructions.
 
Your shopping cart is kept intact and you can still check out at a later time.
About Stearns Products

 
About Stearns Products
 
Stearns is the leading manufacturer of spring-set electrically set motor brakes.
 
Choosing Stearns means you'll receive:
 
  • The broadest line of industrial brakes available from any
    single manufacturer.
  • The shortest lead times.
  • The best quality products to bring you maximum performance.
  • The most consistent and courteous customer service available in
    the power transmission business.
 
We always totally focused on the needs of its customers, setting the standard for brake and clutch quality, on-time performance, and commitment to innovative service.
 
Brakes

Motor Mounted Brakes

Double C-Face
Coupler Brakes

Division 1 Hazardous
Location Brakes

Division 2 Hazardous
Location Brakes

Encoder Brakes

Stainless Steel Motor
Mounted Brakes

Stainless Steel Double
C-Face Coupler Brakes

Marine, Maritime
and Navy Brakes

Servo and Stepper
Motor Brakes

Small Gearmotor Brakes

Small Gearmotor Brakes,
Quiet Operation

Small Gearmotor Brakes,
High Cycling Brake,
NEMA C-Face

Heavy Duty Electromagnetic
Spring Engaged Brakes

European Style
Direct Acting NEMA
C-Face Brakes

Brakes for Portal
Crane Applications

Quiet Brakes

Caliper Brakes

Bearing Supported
Thru-Shaft Brakes

MSHA Certified
Mining Brakes

Power On
Modular Brakes

Mechanical
Lockout Brakes
 

Brakes and
Replacement Parts
 
 
 
Clutches

Heavy Duty Electrically
Engaged Clutches
 

Heavy Duty Spring
Engaged Clutches
 

Power On Modular
Clutch Brakes
 

Power On Modular
Clutches
 

Small Industrial
Clutches
 
 
Solid State Switches for Single Phase Motors (SINPAC)

Switches for Capacitor Start
and Start, Run Motors
 

Switches for Capacitor
Start Motors
 

Switches for Capacitor
Start, Run Motors
 

Switches for Instant Reverse
Capacitor Start Motors
 

Switches for Split
Phase Motors
 
 
Miscellaneous Products

Foot Mounting Kits
 

Industrial Solenoids
 

Motor Frame Adapter Kits
 

Rectifiers
 

Installation and Maintenance Documentation
 
 
This web site is owned and operated by Brake Products, Inc.
Brake Products, Inc.   16751 Hilltop Park Place
  Chagrin Falls, Ohio 44023
  Phone: (440) 543-7962
  Fax:     (440) 543-7963
  Web:   www.brakeproducts.com
  Email: sales@brakeproducts.com
  Federal ID #: 34-1473351
  CAGE Code: 1QTP8
  DUNS# 14-748-2392
  Download: Form W-9
Supplier of Industrial Brake Parts Since 1985