Web orders only - FREE shipping via UPS Ground (continental US only, motor freight excluded)
BRAKE PRODUCTS
61,760
part numbers: Brake Wheels & Discontinued Brake Parts
GEMCO
14,276
part numbers: Motion Control Products
GLEASON
17,960
part numbers: Cable & Hose Management Systems
AERO-MOTIVE
2,589
part numbers: Cable & Hose Management Systems
CUTLER-HAMMER
6,350
part numbers: Electrical Control Products
STEARNS
6,695
part numbers: Motor Mounted Brakes
HUBBELL
8,377
part numbers: Electrical Control Products
SUPERBOLT
102
part numbers: Fastening Solutions
TELEMOTIVE
2,519
part numbers: Radio Remote Control
RENOLD
405
part numbers: Mechanical Power Transmission Products
Aero-Motive Direct
Amazon Store
41 part numbers
Brake Products
Amazon Store
84 part numbers
AUTOMATIC QUANTITY DISCOUNTS
BPI's web orders and web site generated PDF quotations now support quantity discount of up to 10%.
Quotation is valid for 30 days and can be immediately converted into an order.
Web:
www.stearns-direct.com
Email:
sales@stearns-direct.com
Phone:
(888) 861-8777
Motor Mounted Brakes
87,000
182TC-256TC
(1-087-XXX)
87,100
284TC-286UC
(1-087-1XX)
82,000
324TC-405TSC
(1-082-0XX)
86,000
444TC-505USC
(1-086-XXX)
48,100
48C
(1-048-1XX)
56,000
56C-184TC
(1-056-XXX)
Motor Mounted Brakes, Series 48,000
No
Part
Number
Description
Image
Stock
Qty
Price
Each
Qty
Ord'd
Update
Cart
1
STE-1-048-151-00-BB
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [5] = 1.5
Leadwire Position [00] = Internal and external leadwire position
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
-
0
$369.12
2
STE-1-048-151-00-BF
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [5] = 1.5
Leadwire Position [00] = Internal and external leadwire position
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
-
0
$369.12
3
STE-1-048-151-00-BG
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [5] = 1.5
Leadwire Position [00] = Internal and external leadwire position
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [G] = N/A
-
0
$369.12
4
STE-1-048-151-00-BL
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [5] = 1.5
Leadwire Position [00] = Internal and external leadwire position
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
-
0
$369.12
5
STE-1-048-151-00-BM
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [5] = 1.5
Leadwire Position [00] = Internal and external leadwire position
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz
-
0
$369.12
6
STE-1-048-151-00-BN
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [5] = 1.5
Leadwire Position [00] = Internal and external leadwire position
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
-
0
$369.12
7
STE-1-048-151-00-BP
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [5] = 1.5
Leadwire Position [00] = Internal and external leadwire position
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
-
0
$369.12
8
STE-1-048-151-00-BQ
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [5] = 1.5
Leadwire Position [00] = Internal and external leadwire position
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
-
0
$369.12
9
STE-1-048-151-00-KD
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [5] = 1.5
Leadwire Position [00] = Internal and external leadwire position
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [D] = Voltage: 110; 50 Hz
-
0
$369.12
10
STE-1-048-151-00-KF
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [5] = 1.5
Leadwire Position [00] = Internal and external leadwire position
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
-
0
$369.12
11
STE-1-048-151-00-KN
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [5] = 1.5
Leadwire Position [00] = Internal and external leadwire position
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
-
0
$369.12
12
STE-1-048-151-00-KP
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [5] = 1.5
Leadwire Position [00] = Internal and external leadwire position
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
-
0
$369.12
13
STE-1-048-151-00-KQ
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [5] = 1.5
Leadwire Position [00] = Internal and external leadwire position
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
-
0
$369.12
14
STE-1-048-151-01-BB
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [5] = 1.5
Leadwire Position [01] = Internal only
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
-
0
$333.97
15
STE-1-048-151-01-BF
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [5] = 1.5
Leadwire Position [01] = Internal only
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
-
0
$333.97
16
STE-1-048-151-01-BL
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [5] = 1.5
Leadwire Position [01] = Internal only
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
-
0
$333.97
17
STE-1-048-151-01-BN
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [5] = 1.5
Leadwire Position [01] = Internal only
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
-
0
$333.97
18
STE-1-048-151-01-BP
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [5] = 1.5
Leadwire Position [01] = Internal only
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
-
0
$333.97
19
STE-1-048-151-01-BQ
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [5] = 1.5
Leadwire Position [01] = Internal only
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
-
0
$333.97
20
STE-1-048-151-01-KL
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [5] = 1.5
Leadwire Position [01] = Internal only
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
-
0
$333.97
21
STE-1-048-151-01-KP
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [5] = 1.5
Leadwire Position [01] = Internal only
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
-
0
$333.97
22
STE-1-048-151-01-KQ
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [5] = 1.5
Leadwire Position [01] = Internal only
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
-
0
$333.97
23
STE-1-048-161-00-BB
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [6] = 3
Leadwire Position [00] = Internal and external leadwire position
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
-
0
$382.31
24
STE-1-048-161-00-BD
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [6] = 3
Leadwire Position [00] = Internal and external leadwire position
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [D] = Voltage: 110; 50 Hz
-
0
$382.31
25
STE-1-048-161-00-BF
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [6] = 3
Leadwire Position [00] = Internal and external leadwire position
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
-
0
$382.31
26
STE-1-048-161-00-BH
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [6] = 3
Leadwire Position [00] = Internal and external leadwire position
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [H] = Voltage: 220; 50 Hz
-
0
$382.31
27
STE-1-048-161-00-BL
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [6] = 3
Leadwire Position [00] = Internal and external leadwire position
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
-
0
$382.31
28
STE-1-048-161-00-BM
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [6] = 3
Leadwire Position [00] = Internal and external leadwire position
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz
-
0
$382.31
29
STE-1-048-161-00-BO
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [6] = 3
Leadwire Position [00] = Internal and external leadwire position
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [O] = Voltage: 110/220; 50 Hz
-
0
$382.31
30
STE-1-048-161-00-BP
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [6] = 3
Leadwire Position [00] = Internal and external leadwire position
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
-
0
$382.31
31
STE-1-048-161-00-BQ
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [6] = 3
Leadwire Position [00] = Internal and external leadwire position
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
-
0
$382.31
32
STE-1-048-161-00-BR
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [6] = 3
Leadwire Position [00] = Internal and external leadwire position
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [R] = Voltage: 200/400; 60 Hz
-
0
$382.31
33
STE-1-048-161-00-KB
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [6] = 3
Leadwire Position [00] = Internal and external leadwire position
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
-
0
$382.31
34
STE-1-048-161-00-KF
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [6] = 3
Leadwire Position [00] = Internal and external leadwire position
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
-
0
$382.31
35
STE-1-048-161-00-KL
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [6] = 3
Leadwire Position [00] = Internal and external leadwire position
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
-
0
$382.31
36
STE-1-048-161-00-KM
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [6] = 3
Leadwire Position [00] = Internal and external leadwire position
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz
-
0
$382.31
37
STE-1-048-161-00-KN
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [6] = 3
Leadwire Position [00] = Internal and external leadwire position
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
-
0
$382.31
38
STE-1-048-161-00-KP
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [6] = 3
Leadwire Position [00] = Internal and external leadwire position
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
-
0
$382.31
39
STE-1-048-161-00-KQ
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [6] = 3
Leadwire Position [00] = Internal and external leadwire position
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
-
0
$382.31
40
STE-1-048-161-01-BB
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [6] = 3
Leadwire Position [01] = Internal only
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
-
0
$347.16
41
STE-1-048-161-01-BD
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [6] = 3
Leadwire Position [01] = Internal only
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [D] = Voltage: 110; 50 Hz
-
0
$347.16
42
STE-1-048-161-01-BE
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [6] = 3
Leadwire Position [01] = Internal only
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [E] = Voltage: 200; 60 Hz
-
0
$347.16
43
STE-1-048-161-01-BF
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [6] = 3
Leadwire Position [01] = Internal only
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
-
0
$347.16
44
STE-1-048-161-01-BL
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [6] = 3
Leadwire Position [01] = Internal only
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
-
0
$347.16
45
STE-1-048-161-01-BM
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [6] = 3
Leadwire Position [01] = Internal only
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz
-
0
$347.16
46
STE-1-048-161-01-BN
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [6] = 3
Leadwire Position [01] = Internal only
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
-
0
$347.16
47
STE-1-048-161-01-BO
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [6] = 3
Leadwire Position [01] = Internal only
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [O] = Voltage: 110/220; 50 Hz
-
0
$347.16
48
STE-1-048-161-01-BP
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [6] = 3
Leadwire Position [01] = Internal only
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
-
0
$347.16
49
STE-1-048-161-01-BQ
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [6] = 3
Leadwire Position [01] = Internal only
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
-
0
$347.16
50
STE-1-048-161-01-CN
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [6] = 3
Leadwire Position [01] = Internal only
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
-
0
$544.88
51
STE-1-048-161-01-KF
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [6] = 3
Leadwire Position [01] = Internal only
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
-
0
$347.16
52
STE-1-048-161-01-KL
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [6] = 3
Leadwire Position [01] = Internal only
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
-
0
$347.16
53
STE-1-048-161-01-KP
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [6] = 3
Leadwire Position [01] = Internal only
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
-
0
$347.16
54
STE-1-048-161-01-KQ
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [6] = 3
Leadwire Position [01] = Internal only
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
-
0
$347.16
55
STE-1-048-165-00-BU
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [6] = 3
Leadwire Position [00] = Internal and external leadwire position
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [U] = N/A
-
0
$645.96
56
STE-1-048-165-00-BX
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [6] = 3
Leadwire Position [00] = Internal and external leadwire position
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [X] = N/A
-
0
$645.96
57
STE-1-048-165-01-BX
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [6] = 3
Leadwire Position [01] = Internal only
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [X] = N/A
-
0
$610.80
58
STE-1-048-171-00-BB
Stearns Disc Brake Assembly
Part 1-048-171-00-BB
104817100BB
7 = 6 LBS FT Nominal Static Torque
00 = Leadwire Position, Internal and External
B = Hub Bore 5/8 Inch
Keyway 3/16 x 3/32
B = Standard AC Voltage, 115 Volt AC 60 Hz
Ships in 10 Days, WI
Dated 10-2020
-
0
$436.76
59
STE-1-048-171-00-BF
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [7] = 6
Leadwire Position [00] = Internal and external leadwire position
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
-
0
$395.49
60
STE-1-048-171-00-BH
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [7] = 6
Leadwire Position [00] = Internal and external leadwire position
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [H] = Voltage: 220; 50 Hz
-
0
$395.49
61
STE-1-048-171-00-BL
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [7] = 6
Leadwire Position [00] = Internal and external leadwire position
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
-
0
$395.49
62
STE-1-048-171-00-BM
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [7] = 6
Leadwire Position [00] = Internal and external leadwire position
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz
-
0
$395.49
63
STE-1-048-171-00-BN
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [7] = 6
Leadwire Position [00] = Internal and external leadwire position
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
-
0
$395.49
64
STE-1-048-171-00-BP
Stearns Series 48,XXX Brake
Part 1-048-171-00-BP
7 = 6 LB Feet Nominal Static Torque
00 = Internal and external leadwire position
B = 0.625 Inch Hub with a 3/16 x 3/32 keyway
P = 115 / 208 - 230 Volt 60 Hz
Stock to 10 days
Dated 1/18
(6LBS)
-
0
$415.53
65
STE-1-048-171-00-BQ
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [7] = 6
Leadwire Position [00] = Internal and external leadwire position
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
-
0
$395.49
66
STE-1-048-171-00-KF
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [7] = 6
Leadwire Position [00] = Internal and external leadwire position
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
-
0
$395.49
67
STE-1-048-171-00-KQ
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [7] = 6
Leadwire Position [00] = Internal and external leadwire position
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
-
0
$395.49
68
STE-1-048-171-01-BB
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [7] = 6
Leadwire Position [01] = Internal only
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
-
0
$360.33
69
STE-1-048-171-01-BF
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [7] = 6
Leadwire Position [01] = Internal only
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
-
0
$360.33
70
STE-1-048-171-01-BH
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [7] = 6
Leadwire Position [01] = Internal only
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [H] = Voltage: 220; 50 Hz
-
0
$360.33
71
STE-1-048-171-01-BJ
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [7] = 6
Leadwire Position [01] = Internal only
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [J] = N/A
-
0
$505.34
72
STE-1-048-171-01-BL
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [7] = 6
Leadwire Position [01] = Internal only
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
-
0
$360.33
73
STE-1-048-171-01-BM
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [7] = 6
Leadwire Position [01] = Internal only
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz
-
0
$360.33
74
STE-1-048-171-01-BN
Stearns Disc Brake
Part 1-048-171-01-BN
Series 48,XXX Brake
7 = 6 LB FT Nominal Static Torque
1 = Leadwire Position, Internal only
B = Hub Bore 5/8" with a Keyway 3/16" x 3/32"
N = 575 Volt @ 60 Hz
Dated 1/18
-
0
$378.59
75
STE-1-048-171-01-BO
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [7] = 6
Leadwire Position [01] = Internal only
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [O] = Voltage: 110/220; 50 Hz
-
0
$360.33
76
STE-1-048-171-01-BP
Stearns Disc Brake Assembly
Model 1-048-171-01-BP
104817101BP
Series 48,XXX Disc Brake
Nominal Static Torque 6 LB FT
Leadwire Position,Internal only
Hub Bore 5/8
Keyway 3/16 x 3/32
Standard AC Voltage Rating
Voltage: 115 / 208-230 60 Hz
Ships in 2 Weeks, WI Racine
Dated 03-2022
-
0
$434.65
77
STE-1-048-171-01-BQ
Stearns Series 48K Brake
Model 1-048-171-01-BQ
Nominal Static Torque 6 FT LB
Leadwire Position, Internal only
Hub Bore 5/8 Inch
Keyway 3/16" x 3/32"
Standard AC Voltage Rating
Voltage 208 to 230 / 460 60 Hz
190 / 380 Volt @ 50 Hz
-
0
$366.97
78
STE-1-048-171-01-CL
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [7] = 6
Leadwire Position [01] = Internal only
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
-
0
$360.33
79
STE-1-048-171-01-CN
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [7] = 6
Leadwire Position [01] = Internal only
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
-
0
$558.08
80
STE-1-048-171-01-KB
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [7] = 6
Leadwire Position [01] = Internal only
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
-
0
$360.33
81
STE-1-048-171-01-KF
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [7] = 6
Leadwire Position [01] = Internal only
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
-
0
$360.33
82
STE-1-048-171-01-KL
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [7] = 6
Leadwire Position [01] = Internal only
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
-
0
$360.33
83
STE-1-048-171-01-KQ
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [7] = 6
Leadwire Position [01] = Internal only
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
-
0
$360.33
84
STE-1-048-171-01-NL
Stearns Series 48,XXX Brakes:
Nominal Static Torque (lb-ft) [7] = 6
Leadwire Position [01] = Internal only
Hub [N] = N/A
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
-
0
$558.08
Motor Mounted Brakes, Series 56,000
No
Part
Number
Description
Image
Stock
Qty
Price
Each
Qty
Ord'd
Update
Cart
1
STE-1-056-001-00-BBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$377.90
2
STE-1-056-001-00-BEF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [E] = Voltage: 200; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$377.90
3
STE-1-056-001-00-BFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$377.90
4
STE-1-056-001-00-BHF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [H] = Voltage: 220; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$377.90
5
STE-1-056-001-00-BLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$377.90
6
STE-1-056-001-00-BMF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$377.90
7
STE-1-056-001-00-BNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$377.90
8
STE-1-056-001-00-BPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$377.90
9
STE-1-056-001-00-BQF
Stearns Disc Brake Assembly 56k
Part 1-056-001-00-BQF
aka 105600100BQF
Brake, Lightweight Steel Housing
Aluminum Endplate
Fanguard Mounted Brake, IP 54 or IP 55 protection
Mounting Face NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection, IP 54 & 55
Nominal Static Torque 1.5 LB FT
Enclosure IP 23
B = Hub Bore = 5/8
Keyway = 3/16 x 3/32
Q = Standard AC Voltage Rating Voltage: 208 to 230/460 / 60 Hz 190 / 380 50 Hz
F = Leadwire Position, internal and external, left and right standard
Ships in 1 to 2 Weeks, WI
Dated 02-2022
(30LBS) e
-
0
$460.89
10
STE-1-056-001-00-BRF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [R] = Voltage: 200/400; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$377.90
11
STE-1-056-001-00-CBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$377.90
12
STE-1-056-001-00-CLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$377.90
13
STE-1-056-001-00-CQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$377.90
14
STE-1-056-001-00-DHF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [H] = Voltage: 220; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$377.90
15
STE-1-056-001-00-DLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$377.90
16
STE-1-056-001-00-DNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$377.90
17
STE-1-056-001-00-DQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard 5/16
-
0
$377.90
18
STE-1-056-001-00-DRF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [R] = Voltage: 200/400; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$377.90
19
STE-1-056-001-00-ELF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [1] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$377.90
20
STE-1-056-001-00-ENF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [1] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$377.90
21
STE-1-056-001-00-KHF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [1] = IP 23
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [H] = Voltage: 220; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$377.90
22
STE-1-056-001-00-ZBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [1] = IP 23
Hub [Z] = Bore: .460; Keyway: pilot bore
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$377.90
23
STE-1-056-001-00-ZNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [1] = IP 23
Hub [Z] = Bore: .460; Keyway: pilot bore
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$377.90
24
STE-1-056-002-00-BFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$496.56
25
STE-1-056-002-00-BLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$496.56
26
STE-1-056-002-00-BMF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$496.56
27
STE-1-056-002-00-BNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$496.56
28
STE-1-056-002-00-BPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$496.56
29
STE-1-056-002-00-BQF
Stearns Disc Brake
Part 1-056-002-00-BQF
aka 105600200BQF
Series 56,000, 1-056-0XX-00
Brake, Lightweight Steel Housing, Aluminum Endplate
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
Ships in 1 to 2 Weeks
Dated 12-19
-
0
$496.56
30
STE-1-056-002-00-BRF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [R] = Voltage: 200/400; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$496.56
31
STE-1-056-002-00-CPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [2] = IP 54
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$496.56
32
STE-1-056-002-00-CQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [2] = IP 54
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$496.56
33
STE-1-056-002-00-DBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$496.56
34
STE-1-056-002-00-DLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$496.56
35
STE-1-056-002-00-DQF
Stearns Disc Brake
Part 1-056-002-00-DQF
aka 105600200DQF
Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
[Ships in 5 to 7 days]
[Updated 1/19]
-
0
$547.57
36
STE-1-056-002-00-KBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [2] = IP 54
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$496.56
37
STE-1-056-002-00-KPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [2] = IP 54
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$496.56
38
STE-1-056-004-00-BBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [4] = IP 55
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$562.46
39
STE-1-056-004-00-BQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [4] = IP 55
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$562.46
40
STE-1-056-004-00-CQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [4] = IP 55
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$562.46
41
STE-1-056-004-00-DBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [4] = IP 55
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$562.46
42
STE-1-056-004-00-DPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [4] = IP 55
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$562.46
43
STE-1-056-005-00-BUF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [5] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [U] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$641.56
44
STE-1-056-005-00-BYF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [5] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Y] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$641.56
45
STE-1-056-005-00-BZF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [5] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Z] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$641.56
46
STE-1-056-005-00-DYF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [5] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Y] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$641.56
47
STE-1-056-008-00-BXF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [8] = IP 55
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [X] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$826.12
48
STE-1-056-011-00-AQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [A] = Bore: 5/8; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$593.23
49
STE-1-056-011-00-BBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$395.49
50
STE-1-056-011-00-BCF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [C] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$540.50
51
STE-1-056-011-00-BDF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [D] = Voltage: 110; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$395.49
52
STE-1-056-011-00-BEF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [E] = Voltage: 200; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$395.49
53
STE-1-056-011-00-BFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$395.49
54
STE-1-056-011-00-BHF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [H] = Voltage: 220; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$395.49
55
STE-1-056-011-00-BJF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [J] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$540.50
56
STE-1-056-011-00-BLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$395.49
57
STE-1-056-011-00-BMF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$395.49
58
STE-1-056-011-00-BNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$395.49
59
STE-1-056-011-00-BOF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [O] = Voltage: 110/220 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$395.49
60
STE-1-056-011-00-BPF
Stearns Disc Brake
Part 1-056-011-00-BPF
Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
Ships in 2 Weeks, WI
Dated 5-19
-
0
$432.15
61
STE-1-056-011-00-BQF
Stearns Disc Brake Assembly
Part 1-056-011-00-BQF
1056011BQF
3 LB FT
230 / 460 Volt AC 60 Hz
5/8 Inch Inner Hub Diameter
Replaces Old Part 1-055-511-00-BQF
Ships from Stock to 10 Days
Dated 05-2022
-
0
$479.83
62
STE-1-056-011-00-BRF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [R] = Voltage: 200/400; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$395.49
63
STE-1-056-011-00-CFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$395.49
64
STE-1-056-011-00-CLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$395.49
65
STE-1-056-011-00-CMF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$395.49
66
STE-1-056-011-00-CNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$395.49
67
STE-1-056-011-00-CPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$395.49
68
STE-1-056-011-00-CQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$395.49
69
STE-1-056-011-00-DBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$395.49
70
STE-1-056-011-00-DEF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [E] = Voltage: 200; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$395.49
71
STE-1-056-011-00-DFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$395.49
72
STE-1-056-011-00-DHF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [H] = Voltage: 220; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$395.49
73
STE-1-056-011-00-DJF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [J] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$540.50
74
STE-1-056-011-00-DLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$395.49
75
STE-1-056-011-00-DMF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$395.49
76
STE-1-056-011-00-DNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$395.49
77
STE-1-056-011-00-DPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$395.49
78
STE-1-056-011-00-DQF
Stearns Disc Brake Assembly Series 56,000
Part 1-056-011-00-DQF
105601100DQF
Series 56,000 (1-056-0XX-00) Brake
Lightweight Steel Housing, Aluminum Endplate
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
Ships from Stock to 10 Days
Dated 02-2021
-
0
$436.76
79
STE-1-056-011-00-DRF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [R] = Voltage: 200/400; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$395.49
80
STE-1-056-011-00-EBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$395.49
81
STE-1-056-011-00-EFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$395.49
82
STE-1-056-011-00-EHF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [H] = Voltage: 220; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$395.49
83
STE-1-056-011-00-ENF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$395.49
84
STE-1-056-011-00-EOF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [O] = Voltage: 110/220 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$395.49
85
STE-1-056-011-00-EPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$395.49
86
STE-1-056-011-00-EQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$395.49
87
STE-1-056-011-00-FLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [F] = Bore: 1-1/4; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$593.23
88
STE-1-056-011-00-KBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$395.49
89
STE-1-056-011-00-KPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$395.49
90
STE-1-056-011-00-KQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$395.49
91
STE-1-056-011-00-LPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [L] = Bore: 1; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$593.23
92
STE-1-056-011-00-NQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [N] = Bore: 9/16; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$593.23
93
STE-1-056-011-00-OLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [O] = Bore: 11/16; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$593.23
94
STE-1-056-011-00-SLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [S] = Bore: 15/16; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$593.23
95
STE-1-056-011-00-ZNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [Z] = Bore: .460; Keyway: pilot bore
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$395.49
96
STE-1-056-011-00-ZQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [Z] = Bore: .460; Keyway: pilot bore
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$593.23
97
STE-1-056-012-00-ALF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 54
Hub [A] = Bore: 5/8; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$711.87
98
STE-1-056-012-00-AQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 54
Hub [A] = Bore: 5/8; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$711.87
99
STE-1-056-012-00-BBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$514.13
100
STE-1-056-012-00-BCF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [C] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$659.13
101
STE-1-056-012-00-BEF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [E] = Voltage: 200; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$514.13
102
STE-1-056-012-00-BFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$514.13
103
STE-1-056-012-00-BLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$514.13
104
STE-1-056-012-00-BMF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$514.13
105
STE-1-056-012-00-BNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$514.13
106
STE-1-056-012-00-BOF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [O] = Voltage: 110/220 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$514.13
107
STE-1-056-012-00-BPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$514.13
108
STE-1-056-012-00-BQF
Stearns Disc Brake
Part 1-056-012-00-BQF
aka 105601200BQF
Stearns Series 56,000
Housing Lightweight Steel
Mounting Aluminum Endplate
Fanguard Mounted Brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection IP 23, 54 & 55
Nominal Static Torque 3 Foot LBS
Enclosure IP 54
Hub Bore 5/8, Keyway 3/16 x 3/32
Standard AC Voltage Rating [Q] = 208-230/460 60 Hz - 190/380 50 Hz
Lead Wire Position, Standard, internal and external, left and right
Horizontal Mount
Class "B" Coil Insulation
Ships in 10 Days, Racine WI
Dated 12-19
-
0
$566.98
109
STE-1-056-012-00-BSF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [S] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$514.13
110
STE-1-056-012-00-CFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 54
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$514.13
111
STE-1-056-012-00-CLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 54
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$514.13
112
STE-1-056-012-00-CNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 54
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$514.13
113
STE-1-056-012-00-CPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 54
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$514.13
114
STE-1-056-012-00-CQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 54
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$514.13
115
STE-1-056-012-00-DEF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [E] = Voltage: 200; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$637.18
116
STE-1-056-012-00-DFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$514.13
117
STE-1-056-012-00-DLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$514.13
118
STE-1-056-012-00-DPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$514.13
119
STE-1-056-012-00-DQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$514.13
120
STE-1-056-012-00-DRF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [R] = Voltage: 200/400; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$514.13
121
STE-1-056-012-00-ELF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 54
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$514.13
122
STE-1-056-012-00-EQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 54
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$514.13
123
STE-1-056-012-00-ZMF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 54
Hub [Z] = Bore: .460; Keyway: pilot bore
Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$711.87
124
STE-1-056-012-00-ZQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 54
Hub [Z] = Bore: .460; Keyway: pilot bore
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$711.87
125
STE-1-056-014-00-AQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [4] = IP 55
Hub [A] = Bore: 5/8; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$777.79
126
STE-1-056-014-00-BBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [4] = IP 55
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$580.05
127
STE-1-056-014-00-BEF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [4] = IP 55
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [E] = Voltage: 200; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$580.05
128
STE-1-056-014-00-BLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [4] = IP 55
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$580.05
129
STE-1-056-014-00-BNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [4] = IP 55
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$580.05
130
STE-1-056-014-00-BPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [4] = IP 55
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$580.05
131
STE-1-056-014-00-BQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [4] = IP 55
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$580.05
132
STE-1-056-014-00-DMF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [4] = IP 55
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$580.05
133
STE-1-056-014-00-DQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [4] = IP 55
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$580.05
134
STE-1-056-014-80-BQF
Stearns Series 56,000-80 (1-056-0XX-80) Brake, Lightweight Steel Housing, Aluminum Endplate, C-face gasket only, no hub seal:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [4] = N/A
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$522.93
135
STE-1-056-015-00-BUF
Stearns Disc Brake Assembly
Part 1-056-015-00-BUF
105601500BUF
Series 56,000 (1-056-0XX-00) Brake
Lightweight Steel Housing, Aluminum Endplate
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [5] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [U] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
Ships in 1 to 2 Weeks, WI Racine
Dated 10-2020
-
0
$720.25
136
STE-1-056-015-00-BWF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [5] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [W] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$659.13
137
STE-1-056-015-00-BXF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [5] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [X] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$659.13
138
STE-1-056-015-00-BYF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [5] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Y] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$659.13
139
STE-1-056-015-00-BZF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [5] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Z] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$659.13
140
STE-1-056-015-00-CZF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [5] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Z] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$659.13
141
STE-1-056-015-00-DUF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [5] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [U] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$659.13
142
STE-1-056-015-00-DXF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [5] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [X] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$659.13
143
STE-1-056-015-00-DYF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [5] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Y] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$659.13
144
STE-1-056-015-00-DZF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [5] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Z] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$659.13
145
STE-1-056-016-00-BXF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [6] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [X] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$777.79
146
STE-1-056-016-00-BYF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [6] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Y] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$777.79
147
STE-1-056-016-00-BZF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [6] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Z] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$777.79
148
STE-1-056-016-00-CZF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [6] = IP 54
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Z] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$777.79
149
STE-1-056-016-00-DXF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [6] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [X] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$777.79
150
STE-1-056-016-00-DYF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [6] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Y] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$777.79
151
STE-1-056-018-00-BUF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [8] = IP 55
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [U] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$843.70
152
STE-1-056-018-00-BXF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [8] = IP 55
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [X] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$843.70
153
STE-1-056-018-00-DZF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [8] = IP 55
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Z] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$843.70
154
STE-10560210
Stearns / Leeson Brake 175140.00 Rev 2 5/13
-
0
$539.67
155
STE-1-056-021-00-ALF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [A] = Bore: 5/8; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$650.34
156
STE-1-056-021-00-BBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$452.62
157
STE-1-056-021-00-BCF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [C] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$597.62
158
STE-1-056-021-00-BDF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [D] = Voltage: 110; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$452.62
159
STE-1-056-021-00-BEF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [E] = Voltage: 200; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$452.62
160
STE-1-056-021-00-BFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$452.62
161
STE-1-056-021-00-BHF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [H] = Voltage: 220; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$452.62
162
STE-1-056-021-00-BJF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [J] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$597.62
163
STE-1-056-021-00-BKF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [K] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$597.62
164
STE-1-056-021-00-BLF
Stearns Disc Brake Assembly 56K
Part 1-056-021-00-BLF
105602100BLF
Series 56,000 (1-056-0XX-00) Brake
Lightweight Steel Housing, Aluminum Endplate
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
Ships in 2 to 3 Weeks, WI
Dated 05-2022
(10LBS)
-
0
$549.55
165
STE-1-056-021-00-BMF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$452.62
166
STE-1-056-021-00-BNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$452.62
167
STE-1-056-021-00-BOF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [O] = Voltage: 110/220 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$452.62
168
STE-1-056-021-00-BPF
Stearns Magnetic Disc Brake
Part 1-056-021-00-BPF Rev "B"
aka 105602100BPF
Series 56,000 Brake
Lightweight Steel Housing
Aluminum Endplate
Mounting: Fanguard Mounted Brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection IP 23, 54 & 55
2 = Nominal Static Torque 6 FT LB
1 = Enclosure IP 23
B = Bore: 5/8 with a 3/16" x 3/32" Keyway
P = Standard AC Voltage Rating 115 - 230 60 Hz
F = Lead wire position internal and external, left and right, Standard
Class "B" Coil Insulation
Ships in 1 to 2 Weeks, WI
Dated 01-2022
-
0
$546.89
169
STE-1-056-021-00-BQF
Stearns Disc Brake Assembly
Part 1-056-021-00-BQF
105602100BQF
Series 56,000 Brake
Lightweight Steel Housing with Aluminum Endplate
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque 6 FT LB
Enclosure IP 23
Hub Bore 5/8 Inch Keyway: 3/16 x 3/32
Standard AC Voltage Rating 230 /460 Volt 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
Ships from Stock to 2 Weeks
Dated 05-2022
(10LBS)
-
0
$549.55
170
STE-1-056-021-00-BRF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [R] = Voltage: 200/400; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$452.62
171
STE-1-056-021-00-CBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$452.62
172
STE-1-056-021-00-CCF
Stearns Brake 12/13
-
0
$597.62
173
STE-1-056-021-00-CDF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [D] = Voltage: 110; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$452.62
174
STE-1-056-021-00-CFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$452.62
175
STE-1-056-021-00-CLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$452.62
176
STE-1-056-021-00-CNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$452.62
177
STE-1-056-021-00-CPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$452.62
178
STE-105602100CQF
Stearns Brake 1-055-521-00-CQF 6 Foot LB., 230 / 460 Volt AC 60 Hz., Hub Inner Diameter 0.75 Inch, New patented Spline design 9/14
-
0
$439.40
179
STE-1-056-021-00-CQF
Stearns Brake 1-055-521-00-CQF 6 Foot LB., 230 / 460 Volt AC 60 Hz., Hub Inner Diameter 0.75 Inch, New patented Spline design 7/14
-
0
$452.62
180
STE-1-056-021-00-CRF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [R] = Voltage: 200/400; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$452.62
181
STE-1-056-021-00-DBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$452.62
182
STE-1-056-021-00-DEF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [E] = Voltage: 200; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$452.62
183
STE-1-056-021-00-DFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$452.62
184
STE-1-056-021-00-DJF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [J] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$597.62
185
STE-1-056-021-00-DLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$452.62
186
STE-1-056-021-00-DMF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$452.62
187
STE-1-056-021-00-DNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$452.62
188
STE-1-056-021-00-DOF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [O] = Voltage: 110/220 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$452.62
189
STE-1-056-021-00-DPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$452.62
190
STE-1-056-021-00-DQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$452.62
191
STE-1-056-021-00-DRF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [R] = Voltage: 200/400; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$452.62
192
STE-1-056-021-00-EBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$452.62
193
STE-1-056-021-00-EHF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [H] = Voltage: 220; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$452.62
194
STE-1-056-021-00-EPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$452.62
195
STE-1-056-021-00-EQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$452.62
196
STE-1-056-021-00-FPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [F] = Bore: 1-1/4; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$650.34
197
STE-1-056-021-00-FQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [F] = Bore: 1-1/4; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$650.34
198
STE-1-056-021-00-KNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$452.62
199
STE-1-056-021-00-KPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$452.62
200
STE-1-056-021-00-KQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$452.62
201
STE-1-056-021-00-LBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [L] = Bore: 1; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$650.34
202
STE-105602100LF
Stearns Brake, 6 FT LB, 460 volt, No Hub 2/14
-
0
$413.80
203
STE-1-056-021-00-LPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [L] = Bore: 1; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$650.34
204
STE-1-056-021-00-LQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [L] = Bore: 1; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$650.34
205
STE-1-056-021-00-NPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [N] = Bore: 9/16; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$650.34
206
STE-1-056-021-00-OPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [O] = Bore: 11/16; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$650.34
207
STE-1-056-021-00-PPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [P] = Bore: 1-1/16; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$650.34
208
STE-1-056-021-00-PQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [P] = Bore: 1-1/16; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$650.34
209
STE-1-056-021-00-SPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [S] = Bore: 15/16; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$650.34
210
STE-1-056-021-00-ZBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [Z] = Bore: .460; Keyway: pilot bore
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$452.62
211
STE-1-056-021-00-ZMF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [Z] = Bore: .460; Keyway: pilot bore
Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$650.34
212
STE-1-056-021-00-ZPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [Z] = Bore: .460; Keyway: pilot bore
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$452.62
213
STE-1-056-021-00-ZQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [Z] = Bore: .460; Keyway: pilot bore
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$452.62
214
STE-1-056-022-00-AQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [A] = Bore: 5/8; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$769.00
215
STE-1-056-022-00-BBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$571.26
216
STE-1-056-022-00-BDF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [D] = Voltage: 110; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$571.26
217
STE-1-056-022-00-BEF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [E] = Voltage: 200; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$571.26
218
STE-1-056-022-00-BFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$571.26
219
STE-1-056-022-00-BGF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [G] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$716.27
220
STE-1-056-022-00-BLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$571.26
221
STE-1-056-022-00-BMF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$571.26
222
STE-1-056-022-00-BNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$571.26
223
STE-1-056-022-00-BPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$571.26
224
STE-1-056-022-00-BQF
Stearns Disc Brake Assembly 56K
Part 1-056-022-00-BQF
105602200BQF
Series 56,000 (1-056-0XX-00) Brake
Lightweight Steel Housing, Aluminum Endplate
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
Ships in 5 to 7 Day, WI
Dated 03-2021
-
0
$650.69
225
STE-1-056-022-00-CLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$571.26
226
STE-1-056-022-00-CPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$571.26
227
STE-1-056-022-00-CQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$571.26
228
STE-1-056-022-00-DBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$571.26
229
STE-1-056-022-00-DDF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [D] = Voltage: 110; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$571.26
230
STE-1-056-022-00-DEF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [E] = Voltage: 200; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$571.26
231
STE-1-056-022-00-DFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$571.26
232
STE-1-056-022-00-DLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$571.26
233
STE-1-056-022-00-DMF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$571.26
234
STE-1-056-022-00-DNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$571.26
235
STE-1-056-022-00-DPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$571.26
236
STE-1-056-022-00-DQF
Stearns Disc Brake Assembly Series 56,000
Part 1-056-022-00-DQF
Lightweight Steel Housing, Aluminum Endplate
Fanguard Mounted Brakes requiring IP 54 or IP 55 protection
Mounting Face, NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque, 6 Foot LB
Enclosure IP 54
Hub Bore 7/8 Inch Keyway 3/16 x 3/32 Inch
Voltage 230 / 460 @ 60 Hz
Voltage 190 / 380 @ 50 Hz
Leadwire Position F, internal and external, left and right standard
Dated 1/17
-
0
$581.79
237
STE-1-056-022-00-DRF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [R] = Voltage: 200/400; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$571.26
238
STE-1-056-022-00-EBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$571.26
239
STE-1-056-022-00-ELF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$571.26
240
STE-1-056-022-00-ENF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$571.26
241
STE-1-056-022-00-EPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$571.26
242
STE-1-056-022-00-EQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$571.26
243
STE-1-056-022-00-FLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [F] = Bore: 1-1/4; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$769.00
244
STE-1-056-022-00-KLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$571.26
245
STE-1-056-022-00-KNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$571.26
246
STE-1-056-022-00-KQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$571.26
247
STE-1-056-022-00-LNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [L] = Bore: 1; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$769.00
248
STE-1-056-022-00-LQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [L] = Bore: 1; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$769.00
249
STE-1-056-022-00-OQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [O] = Bore: 11/16; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$769.00
250
STE-1-056-022-80-BBF
Stearns Series 56,000-80 (1-056-0XX-80) Brake, Lightweight Steel Housing, Aluminum Endplate, C-face gasket only, no hub seal:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$518.52
251
STE-1-056-022-80-BLF
Stearns Series 56,000-80 (1-056-0XX-80) Brake, Lightweight Steel Housing, Aluminum Endplate, C-face gasket only, no hub seal:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$518.52
252
STE-1-056-022-80-BNF
Stearns Series 56,000-80 (1-056-0XX-80) Brake, Lightweight Steel Housing, Aluminum Endplate, C-face gasket only, no hub seal:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$518.52
253
STE-1-056-024-00-BBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [4] = IP 55
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$637.18
254
STE-1-056-024-00-BFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [4] = IP 55
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$637.18
255
STE-1-056-024-00-BNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [4] = IP 55
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$637.18
256
STE-1-056-024-00-BPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [4] = IP 55
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$637.18
257
STE-1-056-024-00-BQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [4] = IP 55
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$637.18
258
STE-1-056-024-00-BRF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [4] = IP 55
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [R] = Voltage: 200/400; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$637.18
259
STE-1-056-024-00-CLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [4] = IP 55
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$637.18
260
STE-1-056-024-00-DLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [4] = IP 55
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$637.18
261
STE-1-056-024-00-DOF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [4] = IP 55
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [O] = Voltage: 110/220 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$637.18
262
STE-1-056-024-00-DQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [4] = IP 55
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$637.18
263
STE-1-056-024-00-ENF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [4] = IP 55
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$637.18
264
STE-1-056-024-80-BBF
Stearns Series 56,000-80 (1-056-0XX-80) Brake, Lightweight Steel Housing, Aluminum Endplate, C-face gasket only, no hub seal:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [4] = N/A
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$584.44
265
STE-1-056-024-80-BQF
Stearns Series 56,000-80 (1-056-0XX-80) Brake, Lightweight Steel Housing, Aluminum Endplate, C-face gasket only, no hub seal:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [4] = N/A
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$584.44
266
STE-1-056-025-00-BTF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [5] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [T] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$716.27
267
STE-1-056-025-00-BUF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [5] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [U] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$716.27
268
STE-1-056-025-00-BVF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [5] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [V] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$716.27
269
STE-1-056-025-00-BWF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [5] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [W] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$716.27
270
STE-1-056-025-00-BXF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [5] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [X] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$716.27
271
STE-1-056-025-00-BYF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [5] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Y] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$716.27
272
STE-1-056-025-00-BZF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [5] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Z] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$783.04
273
STE-1-056-025-00-CUF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [5] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [U] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$716.27
274
STE-1-056-025-00-CYF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [5] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Y] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$716.27
275
STE-1-056-025-00-CZF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [5] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Z] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$716.27
276
STE-1-056-025-00-DUF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [5] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [U] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$716.27
277
STE-1-056-025-00-DXF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [5] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [X] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$716.27
278
STE-1-056-025-00-DYF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [5] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Y] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$716.27
279
STE-1-056-025-00-DZF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [5] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Z] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$716.27
280
STE-1-056-025-00-EYF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [5] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [Y] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$716.27
281
STE-1-056-025-00-EZF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [5] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [Z] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$716.27
282
STE-1-056-025-00-FZF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [5] = IP 23
Hub [F] = Bore: 1-1/4; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [Z] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$914.00
283
STE-1-056-025-00-LTF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [5] = IP 23
Hub [L] = Bore: 1; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [T] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$914.00
284
STE-1-056-025-00-LXF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [5] = IP 23
Hub [L] = Bore: 1; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [X] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$914.00
285
STE-1-056-025-00-LZF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [5] = IP 23
Hub [L] = Bore: 1; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [Z] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$914.00
286
STE-1-056-026-00-BUF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [6] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [U] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$834.90
287
STE-1-056-026-00-BWF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [6] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [W] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$834.90
288
STE-1-056-026-00-BXF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [6] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [X] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$834.90
289
STE-1-056-026-00-BZF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [6] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Z] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$834.90
290
STE-1-056-026-00-DWF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [6] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [W] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$834.90
291
STE-1-056-026-00-DXF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [6] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [X] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$834.90
292
STE-1-056-026-00-DYF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [6] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Y] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$834.90
293
STE-1-056-026-00-DZF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [6] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Z] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$834.90
294
STE-1-056-026-00-EUF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [6] = IP 54
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [U] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$834.90
295
STE-1-056-028-00-BUF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [8] = IP 55
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [U] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$900.83
296
STE-1-056-028-00-BZF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [8] = IP 55
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Z] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$900.83
297
STE-1-056-031-00?PF
Stearns Brake
10 FT LB
115 / 230 Volt AC
With NEW Splined Design Hub & Disc
Please advise hub size required
1-055-531-00-PF Sr BZ328498 is no longer Mfg 8/15
-
0
$540.50
298
STE-1-056-031-00-BBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$540.50
299
STE-1-056-031-00-BCF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [C] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$685.50
300
STE-1-056-031-00-BDF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [D] = Voltage: 110; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$540.50
301
STE-1-056-031-00-BEF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [E] = Voltage: 200; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$540.50
302
STE-1-056-031-00-BFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$540.50
303
STE-1-056-031-00-BGF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [G] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$685.50
304
STE-1-056-031-00-BHF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [H] = Voltage: 220; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$540.50
305
STE-1-056-031-00-BJF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [J] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$685.50
306
STE-1-056-031-00-BKF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [K] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$685.50
307
STE-1-056-031-00-BLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$540.50
308
STE-1-056-031-00-BNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$540.50
309
STE-1-056-031-00-BPF
Stearns Disc Brake
Part 1-056-031-00-BPF
Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
Ships from Stock
Dated 8-19
-
0
$590.98
310
STE-1-056-031-00-BQF
Stearns Disc Brake Assembly
Part 1-056-031-00-BQF
105603100BQF
10 Ft LB
230 - 460 Volt AC 60Hz
5/8 Inch Hub Bore
Ships from Stock to 1 Week
Dated 04-2021
-
0
$590.98
311
STE-1-056-031-00-BRF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [R] = Voltage: 200/400; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$540.50
312
STE-1-056-031-00-CEF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [E] = Voltage: 200; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$540.50
313
STE-1-056-031-00-CLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$540.50
314
STE-1-056-031-00-CNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$540.50
315
STE-1-056-031-00-CPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$540.50
316
STE-1-056-031-00-CQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$540.50
317
STE-1-056-031-00-DBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$540.50
318
STE-1-056-031-00-DEF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [E] = Voltage: 200; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$540.50
319
STE-1-056-031-00-DFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$540.50
320
STE-1-056-031-00-DHF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [H] = Voltage: 220; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$540.50
321
STE-1-056-031-00-DJF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [J] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$685.50
322
STE-1-056-031-00-DLF
Stearns Brake, same as Sr # 40999G01-0001-2501 6/15
-
0
$540.50
323
STE-1-056-031-00-DMF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$540.50
324
STE-1-056-031-00-DNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$540.50
325
STE-1-056-031-00-DOF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [O] = Voltage: 110/220 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$540.50
326
STE-1-056-031-00-DPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$540.50
327
STE-1-056-031-00-DQF
Stearns Brake, 10 Ft LB, 230 / 460 Volt 60Hz AC, 7/8 Inch Hub Bore 1/15
-
0
$540.50
328
STE-1-056-031-00-DSF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [S] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$685.50
329
STE-1-056-031-00-EBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$540.50
330
STE-1-056-031-00-EFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$540.50
331
STE-1-056-031-00-EHF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [H] = Voltage: 220; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$540.50
332
STE-1-056-031-00-EPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$540.50
333
STE-1-056-031-00-EQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$540.50
334
STE-1-056-031-00-FQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [F] = Bore: 1-1/4; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$738.23
335
STE-1-056-031-00-KBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$540.50
336
STE-1-056-031-00-KLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$540.50
337
STE-1-056-031-00-KNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$540.50
338
STE-1-056-031-00-KPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$540.50
339
STE-1-056-031-00-KQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$540.50
340
STE-1-056-031-00-LBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [L] = Bore: 1; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$738.23
341
STE-105603100LF
Stearns 10 FT LB 1.125 Inch Hub
-
0
$493.17
342
STE-1-056-031-00-LFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [L] = Bore: 1; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$738.23
343
STE-1-056-031-00-LPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [L] = Bore: 1; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$738.23
344
STE-1-056-031-00-LQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [L] = Bore: 1; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$738.23
345
STE-1-056-031-00-NQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [N] = Bore: 9/16; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$738.23
346
STE-1-056-031-00-PLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [P] = Bore: 1-1/16; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$738.23
347
STE-1-056-031-00-PPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [P] = Bore: 1-1/16; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$738.23
348
STE-1-056-031-00-ZLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [Z] = Bore: .460; Keyway: pilot bore
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$738.23
349
STE-1-056-031-00-ZPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [Z] = Bore: .460; Keyway: pilot bore
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$738.23
350
STE-1-056-031-00-ZQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [Z] = Bore: .460; Keyway: pilot bore
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$738.23
351
STE-105603101001
Stearns Brake
230 / 460 Volt 2
-
0
$704.64
352
STE-1056031Z0BQF
Stearns Disc Brake
Part 1056031Z0BQF
With Side Manual Release
and a through Shaft Housing
Ships in
Dated
-
0
$556.60
353
STE-1-056-032-00-ABF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [2] = IP 54
Hub [A] = Bore: 5/8; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$861.27
354
STE-1-056-032-00-BBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$663.54
355
STE-1-056-032-00-BEF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [E] = Voltage: 200; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$663.54
356
STE-1-056-032-00-BFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$663.54
357
STE-1-056-032-00-BLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$663.54
358
STE-1-056-032-00-BMF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$663.54
359
STE-1-056-032-00-BNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$663.54
360
STE-1-056-032-00-BOF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [O] = Voltage: 110/220 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$663.54
361
STE-1-056-032-00-BPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$663.54
362
STE-1-056-032-00-BQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$663.54
363
STE-1-056-032-00-BSF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [S] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$663.54
364
STE-1-056-032-00-CFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [2] = IP 54
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$663.54
365
STE-1-056-032-00-CQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [2] = IP 54
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$663.54
366
STE-1-056-032-00-DBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$663.54
367
STE-1-056-032-00-DEF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [E] = Voltage: 200; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$663.54
368
STE-1-056-032-00-DFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$663.54
369
STE-1-056-032-00-DLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
Ships in 7 to 10 Days
Dated 1/18
-
0
$697.17
370
STE-1-056-032-00-DOF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [O] = Voltage: 110/220 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$663.54
371
STE-1-056-032-00-DPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$663.54
372
STE-1-056-032-00-DQF
Stearns Brake, 10 Ft LB, 230 / 460 Volt 60Hz AC, 7/8 Inch Hub Bore, NEMA 4 Enclosure 1/15
-
0
$663.54
373
STE-1-056-032-00-DRF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [R] = Voltage: 200/400; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$663.54
374
STE-1-056-032-00-EBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [2] = IP 54
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$663.54
375
STE-1-056-032-00-EEF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [2] = IP 54
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [E] = Voltage: 200; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$663.54
376
STE-1-056-032-00-ELF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [2] = IP 54
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$663.54
377
STE-1-056-032-00-EPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [2] = IP 54
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$663.54
378
STE-1-056-032-00-EQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [2] = IP 54
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$663.54
379
STE-1-056-032-00-LQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [2] = IP 54
Hub [L] = Bore: 1; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$861.27
380
STE-1-056-033-00-DQF
Stearns Brake, 10 Ft LB, 230 / 460 Volt 60Hz AC, Dust tight , Water Resistant with a 7/8 Inch Hub Bore 1/15
-
0
$663.54
381
STE-1-056-034-00-BCF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [4] = IP 55
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [C] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$874.47
382
STE-1-056-034-00-BFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [4] = IP 55
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$729.44
383
STE-1-056-034-00-BPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [4] = IP 55
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$729.44
384
STE-1-056-034-00-BQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [4] = IP 55
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$729.44
385
STE-1-056-034-00-CLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [4] = IP 55
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$729.44
386
STE-1-056-034-00-DBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [4] = IP 55
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$729.44
387
STE-1-056-034-00-DLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [4] = IP 55
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$729.44
388
STE-1-056-034-00-DNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [4] = IP 55
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$729.44
389
STE-1-056-034-00-DPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [4] = IP 55
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$729.44
390
STE-1-056-034-00-DQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [4] = IP 55
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$729.44
391
STE-1-056-034-00-EFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [4] = IP 55
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$729.44
392
STE-1-056-034-00-KQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [4] = IP 55
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$729.44
393
STE-1-056-035-00-BUF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [5] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [U] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$804.16
394
STE-1-056-035-00-BWF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [5] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [W] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$804.16
395
STE-1-056-035-00-BZF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [5] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Z] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$804.16
396
STE-1-056-035-00-CZF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [5] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Z] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$804.16
397
STE-1-056-035-00-DUF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [5] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [U] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$804.16
398
STE-1-056-035-00-DWF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [5] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [W] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$804.16
399
STE-1-056-035-00-DXF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [5] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [X] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$804.16
400
STE-1-056-035-00-DYF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [5] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Y] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$804.16
401
STE-1-056-035-00-DZF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [5] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Z] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$804.16
402
STE-1-056-035-00-LXF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [5] = IP 23
Hub [L] = Bore: 1; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [X] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$1,001.89
403
STE-1-056-036-00-BUF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [6] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [U] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$927.19
404
STE-1-056-036-00-BYF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [6] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Y] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$927.19
405
STE-1-056-036-00-DZF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [6] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Z] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$927.19
406
STE-1-056-041-00-010
Stearns Brake
15 FT LB Intermittent Duty
208-230 / 460 Volt AC 60 Hz
4/16
-
0
$628.39
407
STE-1-056-041-00-AQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [A] = Bore: 5/8; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$826.12
408
STE-1-056-041-00-BBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$628.39
409
STE-1-056-041-00-BDF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [D] = Voltage: 110; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$628.39
410
STE-1-056-041-00-BEF
Stearns Disc Brake Assembly 56K
1-056-041-00-BEF
Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [E] = Voltage: 200; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
Ships in 6 Weeks, WI
Dated 06-2021
-
0
$729.60
411
STE-1-056-041-00-BFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$628.39
412
STE-105604100BFQ
Stearns Brake 1/12
-
0
$573.36
413
STE-1-056-041-00-BHF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [H] = Voltage: 220; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$628.39
414
STE-1-056-041-00-BLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$628.39
415
STE-1-056-041-00-BMF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$628.39
416
STE-1-056-041-00-BNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$628.39
417
STE-1-056-041-00-BPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$628.39
418
STE-1-056-041-00-BQF
Stearns Disc Brake Series 56,000
Model 1-056-041-00-BQF
Lightweight Steel Housing & Aluminum Endplate
Fanguard Mounted Brake
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
4 = 15 FT LBS Nominal Static Torque
1 = IP23 Rated Enclosure
B = Hub Bore, 5/8 Inch Diameter with a 3/16 x 3/32 Keyway
Q = Standard AC Voltage Rating
208-230 / 460 Volt AC 60 Hz
190 / 380 Volt AC 50 Hz
F = Standard Leadwire Position, Internal and External, Left and Right
Dated 1/17
-
0
$639.96
419
STE-1-056-041-00-CBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$628.39
420
STE-1-056-041-00-CEF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [E] = Voltage: 200; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$628.39
421
STE-1-056-041-00-CFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$628.39
422
STE-1-056-041-00-CLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$628.39
423
STE-1-056-041-00-CNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$628.39
424
STE-1-056-041-00-CPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$628.39
425
STE-1-056-041-00-CQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$628.39
426
STE-1-056-041-00-DBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$628.39
427
STE-1-056-041-00-DDF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [D] = Voltage: 110; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$628.39
428
STE-1-056-041-00-DEF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [E] = Voltage: 200; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$628.39
429
STE-1-056-041-00-DFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$628.39
430
STE-1-056-041-00-DHF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [H] = Voltage: 220; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$628.39
431
STE-1-056-041-00-DJF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [J] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$773.39
432
STE-1-056-041-00-DLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$628.39
433
STE-1-056-041-00-DMF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$628.39
434
STE-1-056-041-00-DNF
Stearns Disc Brake
Part 1-056-041-00-DNF
105604100DNF
Series 56,000 1-056-0XX-00
Lightweight Steel Housing, Aluminum Endplate
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
Ships in 1 to 2 Weeks, WI
Dated 09-2020
-
0
$687.02
435
STE-1-056-041-00-DOF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [O] = Voltage: 110/220 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$628.39
436
STE-1-056-041-00-DPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$628.39
437
STE-1-056-041-00-DQF
Stearns Disc Brake
Part 1-056-041-00-DQF
105604100DQF
Series 56,000 Brake, Lightweight Steel Housing, Aluminum End Plate
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
4 = 15 FT LB Static Torque
1 = Enclosure IP 23
D = Hub Bore 7/8 Keyway 3/16 x 3/32
Q = Standard AC Voltage Rating 208-230 - 460 60 Hz
190 - 380 50 Hz
F = Lead Wire Position, Standard, internal and external, left and right
Ships from Stock to 2 Weeks
Dated 1-2020
(7LBS)
-
0
$687.02
438
STE-1-056-041-00-DRF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [R] = Voltage: 200/400; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$628.39
439
STE-1-056-041-00-EBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$628.39
440
STE-1-056-041-00-ENF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$628.39
441
STE-1-056-041-00-EPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$628.39
442
STE-1-056-041-00-EQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$628.39
443
STE-1-056-041-00-FFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [F] = Bore: 1-1/4; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$826.12
444
STE-1-056-041-00-FQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [F] = Bore: 1-1/4; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$826.12
445
STE-1-056-041-00-KBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$628.39
446
STE-1-056-041-00-LBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [L] = Bore: 1; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$826.12
447
STE-1-056-041-00-LNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [L] = Bore: 1; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$826.12
448
STE-1-056-041-00-LPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [L] = Bore: 1; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$826.12
449
STE-1-056-041-00-LQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [L] = Bore: 1; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$826.12
450
STE-1-056-041-00-OFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [O] = Bore: 11/16; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$826.12
451
STE-1-056-041-00-PQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [P] = Bore: 1-1/16; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$826.12
452
STE-1-056-041-00-RQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [R] = Bore: 13/16; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$826.12
453
STE-1-056-041-00-ZLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [Z] = Bore: .460; Keyway: pilot bore
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$826.12
454
STE-1-056-041-00-ZNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [Z] = Bore: .460; Keyway: pilot bore
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$826.12
455
STE-1-056-041-00-ZOF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [Z] = Bore: .460; Keyway: pilot bore
Standard AC Voltage Rating [O] = Voltage: 110/220 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$826.12
456
STE-1-056-041-00-ZPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [1] = IP 23
Hub [Z] = Bore: .460; Keyway: pilot bore
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$826.12
457
STE-1-056-042-00-BBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$751.42
458
STE-1-056-042-00-BLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$751.42
459
STE-1-056-042-00-BMF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$751.42
460
STE-1-056-042-00-BNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$751.42
461
STE-1-056-042-00-BPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$751.42
462
STE-1-056-042-00-BQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$751.42
463
STE-1-056-042-00-CBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [2] = IP 54
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$751.42
464
STE-1-056-042-00-CFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [2] = IP 54
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$751.42
465
STE-1-056-042-00-CPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [2] = IP 54
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$751.42
466
STE-1-056-042-00-CQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [2] = IP 54
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$751.42
467
STE-1-056-042-00-DBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$751.42
468
STE-1-056-042-00-DDF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [D] = Voltage: 110; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$751.42
469
STE-1-056-042-00-DFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$751.42
470
STE-1-056-042-00-DHF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [H] = Voltage: 220; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$751.42
471
STE-1-056-042-00-DJF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [J] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$896.43
472
STE-1-056-042-00-DLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$751.42
473
STE-1-056-042-00-DNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$751.42
474
STE-1-056-042-00-DPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$751.42
475
STE-1-056-042-00-DQF
Stearns Disc Brake
Part 1-056-042-00-DQF
Series 56,000 Brake
Lightweight Steel Housing, Aluminum Endplate
Fanguard Mounted Brake
Mounting Face: NEMA 56C, 143TC and 145TC
4.5Inch AK, 5.88 Inch AJ
4 = Nominal Static Torque 15 FT LB
Enclosure IP 54
D = Hub Bore 0.875 with a 3/16 X 3/32 Inch Keyway
Q = Standard AC Voltage Rating
208-230/460 60 Hz
190 / 380 50 Hz
F = Leadwire Position
Internal and External, left and right standard
Ships in 1 Week, WI
Dated 6/17
-
0
$765.28
476
STE-1-056-042-00-EBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [2] = IP 54
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$751.42
477
STE-1-056-042-00-ELF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [2] = IP 54
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$751.42
478
STE-1-056-042-00-EQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [2] = IP 54
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$751.42
479
STE-1-056-042-00-LLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [2] = IP 54
Hub [L] = Bore: 1; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$949.16
480
STE-1-056-042-80-BQF
Stearns Series 56,000-80 (1-056-0XX-80) Brake, Lightweight Steel Housing, Aluminum Endplate, C-face gasket only, no hub seal:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$698.70
481
STE-1-056-042-80-DFF
Stearns Series 56,000-80 (1-056-0XX-80) Brake, Lightweight Steel Housing, Aluminum Endplate, C-face gasket only, no hub seal:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$698.70
482
STE-1-056-044-00-BBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [4] = IP 55
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$817.33
483
STE-1-056-044-00-BCF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [4] = IP 55
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [C] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$962.34
484
STE-1-056-044-00-BLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [4] = IP 55
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$817.33
485
STE-1-056-044-00-BNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [4] = IP 55
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$817.33
486
STE-1-056-044-00-BPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [4] = IP 55
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$817.33
487
STE-1-056-044-00-BQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [4] = IP 55
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$817.33
488
STE-1-056-044-00-DBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [4] = IP 55
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$817.33
489
STE-1-056-044-00-DLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [4] = IP 55
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$817.33
490
STE-1-056-044-00-DMF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [4] = IP 55
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$817.33
491
STE-1-056-044-00-DNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [4] = IP 55
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$817.33
492
STE-1-056-044-00-DQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [4] = IP 55
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$817.33
493
STE-1-056-044-00-ENF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [4] = IP 55
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$817.33
494
STE-1-056-045-00-BUF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [5] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [U] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$892.04
495
STE-1-056-045-00-BWF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [5] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [W] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$892.04
496
STE-1-056-045-00-BXF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [5] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [X] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$892.04
497
STE-1-056-045-00-BZF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [5] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Z] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$892.04
498
STE-1-056-045-00-CUF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [5] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [U] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$892.04
499
STE-1-056-045-00-DUF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [5] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [U] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$892.04
500
STE-1-056-045-00-DVF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [5] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [V] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$892.04
501
STE-1-056-045-00-DXF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [5] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [X] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$892.04
502
STE-1-056-045-00-DYF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [5] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Y] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$892.04
503
STE-1-056-045-00-DZF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [5] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Z] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$892.04
504
STE-1-056-045-00-EXF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [5] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [X] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$892.04
505
STE-1-056-046-00-BUF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [6] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [U] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$1,015.08
506
STE-1-056-046-00-DXF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [6] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [X] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$1,015.08
507
STE-1-056-046-00-DYF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [6] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Y] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$1,015.08
508
STE-1-056-046-00-DZF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [6] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Z] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$1,015.08
509
STE-1-056-048-00-DZF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [4] = 15
Enclosure [8] = IP 55
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Z] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$1,080.98
510
STE-1-056-051-00-ANF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [1] = IP 23
Hub [A] = Bore: 5/8; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$896.43
511
STE-1-056-051-00-BBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$707.48
512
STE-1-056-051-00-BNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$707.48
513
STE-1-056-051-00-BPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$707.48
514
STE-1-056-051-00-BQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$707.48
515
STE-1-056-051-00-CPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$707.48
516
STE-1-056-051-00-CQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$707.48
517
STE-1-056-051-00-DFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$707.48
518
STE-1-056-051-00-DMF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$707.48
519
STE-1-056-051-00-DNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$707.48
520
STE-1-056-051-00-DPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$707.48
521
STE-1-056-051-00-DQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$707.48
522
STE-1-056-051-00-ENF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [1] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$707.48
523
STE-1-056-051-00-EQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [1] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$707.48
524
STE-1-056-051-00-FQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [1] = IP 23
Hub [F] = Bore: 1-1/4; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$905.21
525
STE-1-056-051-00-KQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [1] = IP 23
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$707.48
526
STE-1-056-051-00-LLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [1] = IP 23
Hub [L] = Bore: 1; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$905.21
527
STE-1-056-051-00-LQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [1] = IP 23
Hub [L] = Bore: 1; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$905.21
528
STE-1-056-052-00-BBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$826.12
529
STE-1-056-052-00-BPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$826.12
530
STE-1-056-052-00-BQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$826.12
531
STE-1-056-052-00-CQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [2] = IP 54
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$826.12
532
STE-1-056-052-00-DBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$826.12
533
STE-1-056-052-00-DFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$826.12
534
STE-1-056-052-00-DLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$826.12
535
STE-1-056-052-00-DNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$826.12
536
STE-1-056-052-00-DPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$826.12
537
STE-1-056-052-00-DQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$826.12
538
STE-1-056-052-00-EMF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [2] = IP 54
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$826.12
539
STE-1-056-052-00-ENF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [2] = IP 54
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$826.12
540
STE-1-056-052-00-EQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [2] = IP 54
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$826.12
541
STE-1-056-054-00-DQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [4] = IP 55
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$892.04
542
STE-1-056-055-00-CZF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [5] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Z] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$971.14
543
STE-1-056-055-00-DYF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [5] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Y] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$971.14
544
STE-1-056-055-00-DZF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [5] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Z] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$971.14
545
STE-1-056-055-00-LUF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [5] = IP 23
Hub [L] = Bore: 1; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [U] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$1,168.87
546
STE-1-056-056-00-DZF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [5] = 20
Enclosure [6] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Z] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$1,089.77
547
STE-1-056-061-00-BBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$790.97
548
STE-1-056-061-00-BEF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [E] = Voltage: 200; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$790.97
549
STE-1-056-061-00-BFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$790.97
550
STE-1-056-061-00-BLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$790.97
551
STE-1-056-061-00-BMF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$790.97
552
STE-1-056-061-00-BNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$790.97
553
STE-1-056-061-00-BPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$790.97
554
STE-1-056-061-00-BQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$790.97
555
STE-1-056-061-00-CNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$790.97
556
STE-1-056-061-00-CQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$790.97
557
STE-1-056-061-00-CRF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [R] = Voltage: 200/400; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$790.97
558
STE-1-056-061-00-DBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$790.97
559
STE-1-056-061-00-DCF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [C] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$935.98
560
STE-1-056-061-00-DDF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [D] = Voltage: 110; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$790.97
561
STE-1-056-061-00-DEF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [E] = Voltage: 200; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$790.97
562
STE-1-056-061-00-DFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$790.97
563
STE-1-056-061-00-DGF
Stearns Disc Brake
Part 1-056-061-00-DGF
aka 105606100DGF
Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [G] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
Ships in
Dated 1-19
-
0
$935.98
564
STE-1-056-061-00-DHF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [H] = Voltage: 220; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$755.81
565
STE-1-056-061-00-DJF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [J] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$935.98
566
STE-1-056-061-00-DLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$790.97
567
STE-1-056-061-00-DMF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [M] = Voltage: 415; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$790.97
568
STE-1-056-061-00-DNF
Stearns Disc Brake
Part 1-056-061-00-DNF
Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
Ships in 1 to 2 Weeks, Racine WI
Dated 8-19
-
0
$864.30
569
STE-1-056-061-00-DOF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [O] = Voltage: 110/220 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$790.97
570
STE-1-056-061-00-DPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$790.97
571
STE-1-056-061-00-DQF
Stearns Disc Brake Assembly
Part 1-056-061-00-DQF
105606100DQF
25 FT LB
230 / 460 Volt
Ships in 10 Days WI
Dated 06-2021
(14LBS) H 10" L 12" W 12" Box
-
0
$900.95
572
STE-1-056-061-00-DRF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [R] = Voltage: 200/400; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$790.97
573
STE-1-056-061-00-EFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [1] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$790.97
574
STE-1-056-061-00-ELF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [1] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$790.97
575
STE-1-056-061-00-ENF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [1] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$790.97
576
STE-1-056-061-00-EQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [1] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$790.97
577
STE-1-056-061-00-FFF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [1] = IP 23
Hub [F] = Bore: 1-1/4; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$988.72
578
STE-1-056-061-00-KQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [1] = IP 23
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$790.97
579
STE-1-056-061-00-LHF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [1] = IP 23
Hub [L] = Bore: 1; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [H] = Voltage: 220; 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$988.72
580
STE-1-056-061-00-LQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [1] = IP 23
Hub [L] = Bore: 1; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$988.72
581
STE-1-056-061-00-PQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [1] = IP 23
Hub [P] = Bore: 1-1/16; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$1,252.37
582
STE-1-056-062-00-BBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$909.62
583
STE-1-056-062-00-BLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$909.62
584
STE-1-056-062-00-BPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$909.62
585
STE-1-056-062-00-BQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$909.62
586
STE-1-056-062-00-BRF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [2] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [R] = Voltage: 200/400; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$909.62
587
STE-1-056-062-00-DLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$909.62
588
STE-1-056-062-00-DNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$909.62
589
STE-1-056-062-00-DOF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [O] = Voltage: 110/220 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$909.62
590
STE-1-056-062-00-DPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$909.62
591
STE-1-056-062-00-DQF
Stearns Disc Brake
Part 1-056-062-00-DQF
aka 105606200DQF
Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
[Ships in 5 to 7 days]
[Updated 1/19]
-
0
$993.58
592
STE-1-056-062-00-EBF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [2] = IP 54
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$909.62
593
STE-1-056-062-00-ELF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [2] = IP 54
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$909.62
594
STE-1-056-062-00-ENF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [2] = IP 54
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$909.62
595
STE-1-056-062-00-EPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [2] = IP 54
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$909.62
596
STE-1-056-062-00-EQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [2] = IP 54
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$909.62
597
STE-1-056-062-80-DQF
Stearns Series 56,000-80 (1-056-0XX-80) Brake, Lightweight Steel Housing, Aluminum Endplate, C-face gasket only, no hub seal:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [2] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$856.88
598
STE-1-056-064-00-BNF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [4] = IP 55
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$975.52
599
STE-1-056-064-00-BQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [4] = IP 55
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$975.52
600
STE-1-056-064-00-DEF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [4] = IP 55
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [E] = Voltage: 200; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$966.73
601
STE-1-056-064-00-DLF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [4] = IP 55
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$975.52
602
STE-1-056-064-00-DPF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [4] = IP 55
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$975.52
603
STE-1-056-064-00-DQF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [4] = IP 55
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$975.52
604
STE-1-056-064-00-ENF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [4] = IP 55
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$975.52
605
STE-1-056-065-00-BUF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [5] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [U] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$1,054.62
606
STE-1-056-065-00-BXF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [5] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [X] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$1,054.62
607
STE-1-056-065-00-CUF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [5] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [U] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$1,054.62
608
STE-1-056-065-00-DUF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [5] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [U] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$1,054.62
609
STE-1-056-065-00-DWF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [5] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [W] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$1,054.62
610
STE-1-056-065-00-DXF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [5] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [X] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$1,054.62
611
STE-1-056-065-00-DYF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [5] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Y] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$1,054.62
612
STE-1-056-065-00-DZF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [5] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Z] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$1,054.62
613
STE-1-056-065-00-EUF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [5] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [U] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$1,054.62
614
STE-1-056-065-00-EXF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [5] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [X] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$1,054.62
615
STE-1-056-065-00-EZF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [5] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [Z] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$1,054.62
616
STE-1-056-065-00-LUF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [5] = IP 23
Hub [L] = Bore: 1; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [U] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$1,252.37
617
STE-1-056-066-00-BUF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [6] = IP 54
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [U] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$1,173.27
618
STE-1-056-066-00-DUF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [6] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [U] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$1,173.27
619
STE-1-056-066-00-DZF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [6] = IP 54
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Z] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$1,173.27
620
STE-1-056-068-00-DZF
Stearns Series 56,000 (1-056-0XX-00) Brake, Lightweight Steel Housing, Aluminum Endplate:
Mounting: Fanguard mounted brakes requiring IP 54 or IP 55 protection
Mounting Face: NEMA 56C, 143TC and 145TC 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23, 54 & 55
Nominal Static Torque (lb-ft) [6] = 25
Enclosure [8] = IP 55
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Z] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$1,239.18
621
STE-1-056-101-00-BLF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$443.83
622
STE-1-056-101-00-BNF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$443.83
623
STE-1-056-101-00-BPF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$443.83
624
STE-1-056-101-00-BQF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$443.83
625
STE-1-056-101-00-DEF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [E] = Voltage: 200; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$443.83
626
STE-1-056-101-00-DLF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$443.83
627
STE-1-056-101-00-DNF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$443.83
628
STE-1-056-101-00-DQF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$443.83
629
STE-1-056-102-00-BQF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [2] = IP 56
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$514.13
630
STE-1-056-102-00-CLF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [2] = IP 56
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$562.46
631
STE-1-056-102-00-CQF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [2] = IP 56
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$562.46
632
STE-1-056-102-00-DEF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [2] = IP 56
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [E] = Voltage: 200; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$562.46
633
STE-1-056-102-00-DLF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [2] = IP 56
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$562.46
634
STE-1-056-104-00-BBF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [4] = IP 57
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$628.39
635
STE-1-056-106-00-CXF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [0] = 1.5
Enclosure [6] = IP 56
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [X] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$826.12
636
STE-1-056-111-00-BBF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$461.40
637
STE-1-056-111-00-BFF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$461.40
638
STE-1-056-111-00-BLF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$461.40
639
STE-1-056-111-00-BNF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$461.40
640
STE-1-056-111-00-BPF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$461.40
641
STE-1-056-111-00-BQF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$461.40
642
STE-1-056-111-00-CLF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$461.40
643
STE-1-056-111-00-CQF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$461.40
644
STE-1-056-111-00-DBF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$461.40
645
STE-1-056-111-00-DLF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$461.40
646
STE-1-056-111-00-DQF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$461.40
647
STE-1-056-111-00-ELF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$461.40
648
STE-1-056-111-00-KNF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$461.40
649
STE-1-056-111-00-LLF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [L] = Bore: 1; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$659.13
650
STE-1-056-111-00-LNF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [1] = IP 23
Hub [L] = Bore: 1; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$659.13
651
STE-1-056-112-00-BBF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 56
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$580.05
652
STE-1-056-112-00-BFF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 56
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$580.05
653
STE-1-056-112-00-BLF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 56
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$580.05
654
STE-1-056-112-00-BNF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 56
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$580.05
655
STE-1-056-112-00-BPF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 56
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$580.05
656
STE-1-056-112-00-BQF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 56
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$580.05
657
STE-1-056-112-00-BRF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 56
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [R] = Voltage: 200/400; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$580.05
658
STE-1-056-112-00-CBF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 56
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$580.05
659
STE-1-056-112-00-DFF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 56
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$580.05
660
STE-1-056-112-00-DJF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 56
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [J] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$725.06
661
STE-1-056-112-00-DLF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 56
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$580.05
662
STE-1-056-112-00-DNF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 56
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$580.05
663
STE-1-056-112-00-DQF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [2] = IP 56
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$580.05
664
STE-1-056-114-00-BNF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [4] = IP 57
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$645.96
665
STE-1-056-114-00-BPF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [4] = IP 57
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$645.96
666
STE-1-056-114-00-BQF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [4] = IP 57
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$645.96
667
STE-1-056-115-00-CXF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [5] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [X] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$725.06
668
STE-1-056-115-00-DYF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [5] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Y] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$725.06
669
STE-1-056-115-00-EZF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [5] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [Z] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$725.06
670
STE-1-056-116-00-DXF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [6] = IP 56
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [X] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$843.70
671
STE-1-056-116-00-DYF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [6] = IP 56
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Y] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$843.70
672
STE-1-056-118-00-LTF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [1] = 3
Enclosure [8] = IP 57
Hub [L] = Bore: 1; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [T] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$1,107.36
673
STE-1-056-121-00-BFF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$518.52
674
STE-1-056-121-00-BPF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$518.52
675
STE-1-056-121-00-BQF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$518.52
676
STE-1-056-121-00-CBF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$519.39
677
STE-1-056-121-00-CQF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$518.52
678
STE-1-056-121-00-DFF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$518.52
679
STE-1-056-121-00-DLF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$518.52
680
STE-1-056-121-00-DNF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$518.52
681
STE-1-056-121-00-DQF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$518.52
682
STE-1-056-121-00-ELF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$518.52
683
STE-1-056-121-00-ENF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$518.52
684
STE-1-056-121-00-KBF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$518.52
685
STE-1-056-121-00-KQF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [1] = IP 23
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$518.52
686
STE-1-056-122-00-BFF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 56
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$637.18
687
STE-1-056-122-00-BLF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 56
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$637.18
688
STE-1-056-122-00-BNF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 56
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$637.18
689
STE-1-056-122-00-BOF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 56
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [O] = Voltage: 110/220 50 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$637.18
690
STE-1-056-122-00-BPF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 56
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$637.18
691
STE-1-056-122-00-BQF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 56
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$725.76
692
STE-1-056-122-00-DBF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 56
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$637.18
693
STE-1-056-122-00-DFF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 56
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$637.18
694
STE-1-056-122-00-DLF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 56
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$637.18
695
STE-1-056-122-00-DNF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 56
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$637.18
696
STE-1-056-122-00-DQF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 56
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$637.18
697
STE-1-056-122-00-KLF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [2] = IP 56
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$637.18
698
STE-1-056-122-Q0B-QF
Stearns Brake
-
0
$830.52
699
STE-1-056-124-00-BBF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [4] = IP 57
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$703.08
700
STE-1-056-124-00-BPF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [4] = IP 57
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$703.08
701
STE-1-056-124-00-BQF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [4] = IP 57
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$703.08
702
STE-1-056-125-00-BUF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [5] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [U] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$782.18
703
STE-1-056-125-00-BZF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [5] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Z] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$782.18
704
STE-1-056-125-00-DXF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [5] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [X] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$782.18
705
STE-1-056-125-00-DYF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [5] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Y] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$782.18
706
STE-1-056-125-00-DZF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [5] = IP 23
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Z] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$782.18
707
STE-1-056-125-00-EZF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [5] = IP 23
Hub [E] = Bore: 1-1/8; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [Z] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$782.18
708
STE-1-056-125-00-KTF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [5] = IP 23
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [T] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$782.18
709
STE-1-056-125-00-KUF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [5] = IP 23
Hub [K] = Bore: 1/2; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [U] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$782.18
710
STE-1-056-125-00-LTF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [5] = IP 23
Hub [L] = Bore: 1; Keyway: 1/4 x 1/8
Standard AC Voltage Rating [T] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$979.93
711
STE-1-056-126-00-DXF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [2] = 6
Enclosure [6] = IP 56
Hub [D] = Bore: 7/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [X] = N/A
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$900.83
712
STE-1-056-131-00-AFF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [A] = Bore: 5/8; Keyway: 1/8 x 1/16
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$804.16
713
STE-1-056-131-00-BFF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$606.41
714
STE-1-056-131-00-BLF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$606.41
715
STE-1-056-131-00-BNF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$606.41
716
STE-1-056-131-00-BPF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [P] = Voltage: 115/208-230; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$606.41
717
STE-1-056-131-00-BQF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [B] = Bore: 5/8; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [Q] = Voltage: 208-230/460; 60 Hz (190/380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$606.41
718
STE-1-056-131-00-CBF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [B] = Voltage: 115; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$606.41
719
STE-1-056-131-00-CFF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [F] = Voltage: 230; 60 Hz (190; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$606.41
720
STE-1-056-131-00-CLF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [L] = Voltage: 460; 60 Hz (380; 50 Hz)
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$606.41
721
STE-1-056-131-00-CNF
Stearns Series 56,100 (1-056-1XX) Brake, Die Cast Aluminum Enclosure:
Release Type: Internal Lever, Non-Maintained
Mounting: Fanguard-mounted brakes requiring IP 56 or IP 57 protection
Mounting Face: NEMA 56C, 143TC and 145TC , 4.5" AK, 5.88" AJ
Enclosure Protection: IP 23; 56 & 57
Visual Wear Indicator
Nominal Static Torque (lb-ft) [3] = 10
Enclosure [1] = IP 23
Hub [C] = Bore: 3/4; Keyway: 3/16 x 3/32
Standard AC Voltage Rating [N] = Voltage: 575; 60 Hz
Leadwire Position [F] = Lead wire position (internal and external, left and right) standard
-
0
$606.41